4.3 Other Specification

4.3.1 Inrush Current: 
          No damage at 25 C cold start.

4.3.2 Power Efficiency:
          70% (min.) at full load, 115Vac and 230Vac input. Test below as:

4.3.4 Hold-Up Time:
          8msec (minimum) at 80% of full load, at 230AC input.

4.3.5 Power Good Delay:
          100-500 msec.

4.3.6 Power Fail Delay:
           >1 msec.

4.3.7 Turn-On Delay Time:
          2000 msec max. 

4.3.8 Rise Time:
          20ms max at full load.

4.3.9  MTBF at 25 C(demonstrated)
          100KHrs minimum

4.3.3 Note:
         The combined power of +5V and +3.3V is 140W max.
         Peak currents may last up to 17 seconds with not more than 
         one occurrence per minute.
         Add 0.1uF and 10uF capacitors across output terminal during 
         ripple & noise test.

+5V     +12V1     +12V2     +3.3V      -12V      +5Vsb

AC:115V      18.0A         14A            14A         10.7A           0.3A          3.0A

AC:230V      18.0A         14A            15A           13A            0.3A          3.0A

10

09

Total Output Connector

100

mV

100

mV

100

mV

+3.3 V

+5 V

+12 V

-12 V

+5 VSB

30 A

28 A

16 A

17 A

0.3 A

3.0 A

0.5 A

1.0 A

0.3 A

1.0 A

0.0 A

0.0 A

+5% ~ -5%

+5% ~ -5%

+5% ~ -5%

+5% ~ -5%

+10% ~ -10%

+5% ~ -5%

150

mV

150

mV

150

mV

Min. 
Load

Ripple
V(p-p)

Load
Reg.

Max.
Load

+12 V

1

2

--

--

--

--

Peak
 load

3.5 A

4-pin Peripheral 

Connector X 8

    and Floppy 

 Connector X 2

24-pin Main

Connector X1 

& 4-pin +12V X1 

6-pin 

PCI Express 

Connector

 

X 2

5-pin S-ATA 

Connector X 4

Technology Features 

 Cable Application

Intelligent Cable Management:

All cables are sleeved with black mesh cable sleeving
Optimum air-flow currents within the chassis

PCI-Express 

Connector

Dual +12V Rails

New 24(20) pin 

Main Connector

140mm fan - High

thermal performance

--

170 X 140 mm

W0134_TR2 Cable Management 550WW_

_A07040901

Summary of Contents for TR2 RX 700w

Page 1: ...y Thermaltake TR2 Power Supply User s M anual TR2 RX Cable Management 550W Power Supply TR2 RX 550W Cable Management power Supply ATX 12V 2 2 Version www thermaltake com thermaltake thermaltake com Revision A 2007 04 www tr2tt com sales tr tr2tt com E193705 170 X 140 mm 170 X 140 mm W0134_TR2 Cable Management 550WW_ _A07040901 ...

Page 2: ...Cable Management 550W PC Power Supply that is suitable for all of your modern PC power needs Please take the time in familiarize yourself with the power supply its connectors and the contents of this manual before proceeding with the installation of the power unit You will need a Phillips crosshead screwdriver perhaps your PC case manual and most certainly your motherboard manual 1 Introduction 6 ...

Page 3: ......

Page 4: ...eral devices refer to the rest of this manual to match the various one way key locked connectors to the motherboard and accessories 3 3 6 Connect the 6 pin PCI Express connector to PCI Express graphic card if you need Note Please read the user manual supplied with your graphic card for detail usage instructions 3 3 7 Close the computer case 3 3 8 Make sure your power supply switch is on OFF positi...

Page 5: ... Color Orange Blue Black Green Black Black Black N C Red Red Red Black Pin 1 2 3 4 5 6 7 8 9 10 11 12 Pin 13 14 15 16 17 18 19 20 21 22 23 24 Color Signal Pin Yellow 12V DC 1 1 Yellow 12V DC 1 2 Yellow 12V DC 1 3 Black COM 4 Black COM 5 Black COM 6 Gray 4 1 Output Specification 4 Product Specification Floppy disk connector 4 pin Peripheral connector 4 pin 12V connector 4 pin 1 4 05 06 Color Signal...

Page 6: ...t 230Vac input 115 VAC 230 VAC INPUT Input Voltage Input Frequency Range Input Current Hold up Time Efficiency Net Weight Passive PFC PFC Power Factor Correction Noise 550 Watts Maximum Power SPECIFICATION 160mm L X150mm W X86mm H Unit Size DIMENSIONS Over Voltage Protection Recycle AC to Reset 100 500 ms P G Signal Cooling System Switches 10 0A 5 0A INPUT DIMENSIONS P N W0134 16dB at 1300 RPM 2 2...

Page 7: ...uF and 10uF capacitors across output terminal during ripple noise test 5V 12V1 12V2 3 3V 12V 5Vsb AC 115V 18 0A 14A 14A 10 7A 0 3A 3 0A AC 230V 18 0A 14A 15A 13A 0 3A 3 0A 10 09 Total Output Connector 100 mV 100 mV 100 mV 3 3 V 5 V 12 V 12 V 5 VSB 30 A 28 A 16 A 17 A 0 3 A 3 0 A 0 5 A 1 0 A 0 3 A 1 0 A 0 0 A 0 0 A 5 5 5 5 5 5 5 5 10 10 5 5 150 mV 150 mV 150 mV Min Load Ripple V p p Load Reg Max Lo...

Page 8: ...ort Protection All outputs to GND 4 5 Environment 4 5 1 Operating Temp 0 C to 40 C 4 5 2 Storage Temp 20 C to 70 C 4 5 3 Operating Humidity 20 to 90 non condensing 4 5 4 Storage Humidity 5 to 95 non condensing 4 5 5 Operating Altitude 0 to 10 000 feet 4 5 6 Storage Altitude 0 to 50 000 feet 4 7 EMI Safety 4 7 1 Conducted EMI 1 Meet FCC Class B 2 Meet CISPR 22 Class B 3 Meet VCCI Class B 4 7 2 Safe...

Page 9: ...utput The fan or fans are motionless Check 1 1 Is the AC inlet plug firmly plugged into the PSU inlet socket 1 2 Is the wall socket extension power cord power strip or surge protector in use fully functional and wall power switch turned ON 1 3 Is the Main Board socket 24pin plug fully and firmly inserted Condition 2 The fan or fans began rotating and then stopped The system hangs without proceedin...