background image

80 PLUS Verification and Testing Report

TYPICAL EFFICIENCY (50% Load):

AVERAGE EFFICIENCY :

80 PLUS COMPLIANT:

YES

Value

Units

100-240 Volts

13

Amps

47-63

Hz

1000

Watts

Note: All measurements were taken with input voltage at 115 V nominal and 60 Hz.

Input AC Current Waveform (ITHD = 4.9%, 50% Load)

I

RMS

PF

A

-12V

3.3V

5V*

5VSB

2.21

0.98

7.6%

20%

Light

249

12/0.2

3.3/3.6

5.1/3.6

5.1/0.7

202

81.05%

5.16

1.00

4.9%

50%

Typical 

590

11.9/0.4

3.2/9.1

5/9.1

4.9/1.7

500

84.71%

10.47

1.00

3.6%

100%

Full

1202

12/0.8

3.1/18.1

4.9/18.2

4.7/3.4

983

81.77%

Tested by Electric Power Research Institute, Knoxville, TN.

8/22/2007

Efficiency 

%

Rated Output Power

Load 

(%)

Rated Specifications

Input Voltage
Input Current

I

THD

 (%)

Input 
Watts

Fraction 
of Load

DC Terminal Voltage (V)/ DC Load Current (A)

Output 

Watts

12V (cumulative of 12V1, 12V2, etc.)

12.1/13.8

12/34.3

11.8/68.6

Test Date 

Input Frequency

334.1

Type

Ecos ID #

Model Number
Serial Number
Year

EPS12V

NA
2007

Manufacturer

84.71%
82.51%

Thermaltake
W0155RU

Input and Output Power

Input Watts

Output Watts

0

200

400

600

800

1000

1200

1400

20%

50%

100%

Loading (% of Rated Output Power)

P

o

w

e

(W

a

tt

s

)

Efficiency of the Power Supply

30%

40%

50%

60%

70%

80%

90%

0%

25%

50%

75%

100%

125%

Loading (% of Rated Output Power)

E

ff

ic

ie

n

c

y

 (

%

)

Efficiency %

These tests were conducted as a part of the 80 PLUS program.  80 PLUS is 
a computer buy-down program to promote high-efficiency power supplies 
(greater than 80% efficiency in the active mode) in desktop computers and 
desktop-derived servers.

Input Current and Voltage Waveforms

-200

-150

-100

-50

0

50

100

150

200

0

0.003

0.006

0.009

0.012

0.015

Time (s)

V

o

lt

a

g

e

 (

V

)

-15

-10

-5

0

5

10

15

C

u

rr

e

n

(A

)

Voltage 

Current 

Reviews: