INSTALLATION INSTRUCTIONS
17
commISSIonInG
!
materIal loSSeS
Never operate the equipment outside the temperature range 0 °C to + 42 °C.
note
At temperatures below - 10 °C (e.g.
transport/storage), the safety temperature cut-out may respond.
Press
the reset button after the temperature is much higher than -10 °C.
Only approved contractors may commission this equipment and instruct the owner in its use.
f
f
Fill, vent and thoroughly flush the device.
f
f
Check the safety assembly.
Inform the user that water may drip from the safety valve whilst the water is being heated up.
f
f
Switch ON the power supply
Safety equpment anD maIntenance
Only qualified contractors must carry out the installation in accordance with these instructions.
WarnInG electrocutIon
Maintenance work, such as checking the electrical safety, must only be carried out by an electrician.
always disconnect the power supply before working on the water heater.
note
You may remove the air intake grille if there is not enough room for maintenance work above the appliance
even after its cover has been removed (Refer chapter “Installation”, section “Minimum clearances”for min-
imum clearance area).
The air intake grille is secured with spring nuts. The inside of the air intake grille features an all-round ad-
hesive sealing strip.
f
f
Never remove the sealing strip.
f
f
Always use the spring nuts during reassembly.
f
f
Refit the air intake grille after completing the maintenance and repair work.
26
_0
3_0
1_
18
77
1
1
Removeable air intake grille with an all-around adhesive sealing strip on the inside
Summary of Contents for TIHP 300
Page 1: ...INSTALLATION INSTRUCTIONS INTEGRATEDHEATPUMP300L FOR MODEL TIHP 300 OPERATION AND ...
Page 2: ...2 INSTALLATION INSTRUCTIONS ...
Page 25: ...INSTALLATION INSTRUCTIONS 25 Notes ...
Page 26: ...26 INSTALLATION INSTRUCTIONS Notes ...
Page 27: ...INSTALLATION INSTRUCTIONS 27 Notes ...
Page 28: ...Works for you www reece com au Thermann 313698 37792 8934 ...