Congratulations

The new Thermapen Mk4 is a precision thermometer used for many applications, including 

cooking. With proper care, it will offer accurate measurements for many years. The new 

Mk4 Thermapen includes several new features, including: intelligent backlight, auto-rotating 

display, user-selectable sleep interval, motion-activated wake-up mode, and added water 

resistance. 

Instrument Operation

The unit is switched on by unfolding the thermocouple probe 

until the display comes on. Conversely, the unit is turned 

off by folding the probe away and lightly pressing the tip 

into the rubber probe retainer located at the bottom rear of 

the instrument. It is recommended to store the probe in the 

closed position when not in use. 

Do not force the probe further than 180° when opening 

or damage to the rotating  hub may occur.

The micro-thermocouple sensor is located at the tip of the probe shaft. Minimum immersion 

is only 1/8" (3 mm). For best results, immerse or penetrate the probe into the food item so the 

probe tip is in the place you want to measure. In food, this should normally be at the center 

of the thickest part. 

The Thermapen will read to within 1°F of the actual 

temperature of an ice bath within three seconds. Reading 

times in other foods may vary slightly.

Do not immerse the probe all the way to the plastic 

rotating hub. Avoid getting flour, moisture, or oil on the 

hub itself. Although there is an O-ring seal, oils can 

work their way past the seal and accumulate inside 

the hub and may cause failure. The probe tip is sharp. 

Use caution to avoid injury. Do not “stab” the material 

to be measured. Use steady force to penetrate meats 

or semi-solids. Avoid bone. Do not lift or flip heavy 

meats with the probe tip. The probe shaft is hollow and 

contains a sensor. If bent, it may fail.

Rotating hub

0.1”

0.55”

0.65”

0.125 dia”

Probe Tip

Sensor location

Minimum immersion 1/8"

Thermapen

® 

Mk4

Operating Instructions

1

2

3

4

5

6

7

8

165°F

140°F

Summary of Contents for Mk4

Page 1: ...s located at the tip of the probe shaft Minimum immersion is only 1 8 3 mm For best results immerse or penetrate the probe into the food item so the probe tip is in the place you want to measure In food this should normally be at the center of the thickest part The Thermapen will read to within 1 F of the actual temperature of an ice bath within three seconds Reading times in other foods may vary ...

Page 2: ...until SLEEP is shown at the top of the display Press the SET button to step through the sleep interval settings from 10 seconds to 180 seconds in 10 second intervals or to turn the sleep function off Press MENU to store the sleep interval and the unit will enter sleep mode at the specified number of seconds without movement detected END will flash momentarily to show that all settings are saved No...

Page 3: ...hen Bat and then shut down To continue using the instrument replace the battery Replacing the Battery The battery is pre installed on your new Thermapen Mk4 and should last up to 3 000 hours Should you need to replace the battery loosen the battery cover screw using a Phillips screwdriver to remove the battery cover Pull up on the spring loaded battery clip and tip the unit to allow the battery to...

Page 4: ...nts or workmanship The warranty does not cover fair wear and tear abnormal use or storage incorrect use neglect water damage misapplication modification or abuse ThermoWorks reserves the right to evaluate all warranty claims before any action is taken and at its discretion may repair or replace without charge For complete warranty details visit www thermoworks com Thermapen Accessories available a...

Reviews: