WATER CONNECTIONS
1. All water pipework must comply with national regulations and local water piping codes.
2. No matter whether installing the appliance upright or upside down, please connect the
inlet connection (blue nozzle on the unit) to the cold water inlet pipe; connect the outlet
connection (red nozzle on the unit) to the hot water outlet pipe.
3. The unit should be connected directly to the mains water supply. Flush pipes first with
water to remove any debris or loose particles.
4. It is required that one uses G1/2” water connections to fit the appliance. Please connect the
inlet and outlet pipe in the correct order mentioned above.
5. Please remember to install rubber seal O-rings at the connections. When all water
connections are completed, check for leaks and take corrective action before proceeding
to turn the unit on.
ELECTRICAL CONNECTION
1. All electrical work must comply with national regulations and local electrical codes
2. The unit must be connected to a properly grounded dedicated branch circuit of
proper voltage rating.
3. While feeding the cable to terminal blocks/circuit breaker, please make sure the
metal wire ends and the terminal blocks touch and can be sealed completely. Then
tighten the screws up to make sure the full current can go through.
9
ThermaQ Specification Hotline 01924 270847
Inlet
Outlet
Fig 6.
Fix the
application on
the wall.
Fig 7.
Connect
the correct water
pipes to the water
inlet and water
outlet connections,
remembering
to install rubber
O-rings to ensure a
watertight seal.
Cont.
2890/ElectricPackagingManuals/A5.indd 9