background image

HydroVive Installation Instructions

3

THERMASOL.COM  

I

  800.776.0711

Tools and Materials

2

Parts Enclosed:

Silicone

25' Yellow M12 Cable

Item 03-7149-25

Wood Screw

#10 x 3.5"  x 4

Installation instructions

Materials needed:

o

   PDM (Item 10-8147)

o

   Compatible controller

o

   Drill

Tile Cutter

o

  Ply Wood Backing Board

o

  36" long 3/8" Compression Flexible Water Line

o

  Separate water volume control diverter  

  with shut off valve

(Fig. 1) Installation Profile View

Compatible Controls:

ThermaTouch 7" and 10"

HydroVive Light, Sound, 

Rain Head fixture and hardware

Item HVLSRSQ-XX

Joist

Mounting B
4x #4 Flat Head Screw

Plywood

Waterproof 
Backing

Mortar

Finished  
Shower Surface

RTV Silicone Sealant

#10 Flat Head Screw

O-Ring (-016)
Screw Cover

25' Audio Cable 

Item 03-7140

Summary of Contents for 652592089750

Page 1: ...Wellness Steam ThermaTouch10 Hydrovive18 Package OVER 60 YEARS OF STEAM SHOWER INNOVATION Installation Manual For Tutorials and Troubleshooting visit www thermasol com solutions ...

Page 2: ...ThermaTouch Control OVER 60 YEARS OF STEAM SHOWER INNOVATION Installation Manual For Tutorials and Troubleshooting visit www thermasol com solutions TT10 XX ...

Page 3: ...NG INTO THE STEAMHEAD ITSELF OR INTO THE STREAM OF STEAM EMITTING FROM THE STEAMHEAD WILL CAUSE SERIOUS BURNS OR PHYSICAL INJURY IF YOU ARE FEELING UNCOMFORTABLE DIZZY FAINT OR STARTING TO FALL ASLEEP IMMEDIATELY EXIT THE STEAM ROOM DO NOT USE STEAM ROOM IF YOU ARE UNDER THE AGE OF 16 UNLESS SUPERVISED BY AN ADULT THERMASOL STEAM BATH GENERATORS ARE NOT DESIGNED TO BE USED FOR SPACE HEATING PURPOS...

Page 4: ...OUNDING WIRE ON THE BACK OF THE CONTROLLER PRIOR TO INSTALLTION OF YOUR THERMATOUCH LOCATE THE CLOSEST EARTH GROUND COPPER WATER PIPE AND ATTACHED THE WIRE AS SHOWN BELOW IF YOU HAVE ANY QUESITONS ABOUT THIS PROCESS PLEASE CONTACT US AT SUPPORT THERMASOL COM OR BY PHONE AT 800 776 0711 COPPER WATER PIPE EARTH GROUNDING WIRE GROUNDING STRAP ...

Page 5: ...tem TT10 XX Shower wall Shower wall Mud Ring goes inside wall opening Finished wall must be flush with the mud ring Power Supply Brick Item 03 7142 Materials needed o ThermaTouch control o M12 cable o Silicone o Power Distribution Module PDM o Mud Ring o Ethernet Cable with RJ 45 Connector not supplied o Other materials as required Back of Control REMINDER in order to receive software updates the ...

Page 6: ...team line or route it in a manner so that the hot steam line could melt the cable Any damage to the control cable will result in the control not working properly Carefully connect the data cable to the PDM and control BEFORE turning power on to the generator or PDM ON Turn Clockwise OFF Turn Counter Clockwise Do not staple strain or damage data cable Align pins to receptacle visually before tighte...

Page 7: ...ollect behind it Place the control on the wall pressing firmly You may need to tape the control into place until the silicone dries Be careful not to harm the wall or control with the tape Let dry for 24 hours before using steam bath A 5 Sealing Control Side View of Surface Mount Control Back Side of Surface Mount Control ThermaTouch Control Installation Instructions 6 THERMASOL COM I 800 776 0711...

Page 8: ...ng ThermaTouch to Generator 6b Connecting ThermaTouch to Serenity Light Sound Rainhead ThermaTouch Control Installation Instructions 7 THERMASOL COM I 800 776 0711 Read warnings on page 2 For illustrative purposes only Consult with qualified professional for steam room construction details ...

Page 9: ...8 Cable 6c Connecting ThermaTouch to Digital Shower 6b Connecting Total Wellness Package ThermaTouch Control Installation Instructions 8 THERMASOL COM I 800 776 0711 Read warnings on page 2 For illustrative purposes only Consult with qualified professional for steam room construction details ...

Page 10: ...or copper tubing from unit to steamhead rough in fitting as permitted by code A B The steam line can run up and then down once or horizontal but never run down and then up If it does a steam trap will be produced at the low point blocking the flow of steam Insulate the steam outlet piping if the piping run exceeds 10 feet or is exposed to cold areas Use steam rated insulation Pitch angle steam lin...

Page 11: ...t be done from backside of finshed space For new framing Mount and install rough in fitting to be flush with finished wall Connect a 1 2 NPT brass pipe or copper tubing to the steam outlet union not included on the generator running the pipe to the steam head location in the wall to connect with the steamhead rough in fitting It is very important that the pipe is firmly secured to the wall so that...

Page 12: ...nt steamhead with facing up to allow aromatherapy well to dispense steam For detailed installation instructions of the steamhead please see Installation section in thermasol com customer support Apply a small amount of supplied lubricant directly on the o rings Once the shower wall is complete and the housing is sealed to the wall remove the protective cap and insert the steamhead into housing Use...

Page 13: ...on Instructions 12 THERMASOL COM I 800 776 0711 Read warnings on page 2 For illustrative purposes only Consult with qualified professional for steam room construction details Visit www thermasol com solutions Click on Troubleshoot then click on ThermaTouch Control Error Codes ...

Page 14: ...1958 STEAM WAY ROUND ROCK TX 78665 PHONE 800 776 0711 FAX 800 556 5257 WWW THERMASOL COM 81227_A ...

Page 15: ...HydroVive OVER 60 YEARS OF STEAM SHOWER INNOVATION Installation Manual For Tutorials and Troubleshooting visit www thermasol com solutions HVLSRSQ XX ...

Page 16: ...HERMASOL UNIT WITHOUT CONSULTING WITH YOUR ALLERGIST OR DOCTOR BEFORE USE THESE PRODUCTS MAY BE HAZARDOUS TO YOUR HEALTH DO NOT USE STEAM ROOM WHILE UNDER THE INFLUENCE OF ALCOHOL OR DRUGS AS THIS CAN BE HAZARDOUS TO YOUR HEALTH YOUR SHOWER MAY BE A SLIP AND FALL HAZARD CHECK WITH YOUR CONTRACTOR OR FLOORING MANUFACTURER REGARDING THE SAFE USE OF YOUR FLOORING IN A STEAM APPLICATION SLIPPING AND F...

Page 17: ... Cutter o Ply Wood Backing Board o 36 long 3 8 Compression Flexible Water Line o Separate water volume control diverter with shut off valve Fig 1 Installation Profile View Compatible Controls ThermaTouch 7 and 10 HydroVive Light Sound Rain Head fixture and hardware Item HVLSRSQ XX Joist Mounting Bracket 4x 4 Flat Head Screw Plywood Waterproof Backing Mortar Finished Shower Surface RTV Silicone Sea...

Page 18: ...ill be completed from inside the shower NOTE HydroVive weighs 37 lbs It must be mounted to a framed structure that can support its weight 16 7 16 7 14 5 14 25 14 25 Cutout Sizing PDM Sold and ships with ThermaTouch control ThermaTouch Control sold separately 25 Yellow M12 Cable Item 03 7149 25 ships with ThermaTouch control Digital Shower Valve By adding the Digital Shower Valve you replace multip...

Page 19: ...l ThermaSol devices prior to making any connections Align the notches at the top of the mounting guides with the mounting brackets and slip them over to firmly secure the HydroVive in place while the connections are made With HydroVive secured on the mounting brackets angle the unit to gain access and connect all cables Double check to ensure that all connections are correct before moving forward ...

Page 20: ...e ceiling and rest it on the highest hook you can reach Use the 3 5 included mounting screws and gradually insert them a little at a time to evenly lift the HydroVive into position to create a seal with the previously applied silicone DO NOT OVERTIGHTEN Once the HydroVive is in position and the silicone seal is created no further clamping force is necessary Sealing HydroVive 7 Apply silicone along...

Page 21: ... cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or re...

Page 22: ...1958 STEAM WAY ROUND ROCK TX 78665 PHONE 800 776 0711 FAX 800 556 5257 WWW THERMASOL COM 81253_A ...

Page 23: ...1958 STEAM WAY ROUND ROCK TX 78665 PHONE 800 776 0711 FAX 800 556 5257 WWW THERMASOL COM 81285_NC ...

Reviews: