User Manual
3200 Series
70 Part No HA028651 Issue 11.0 July-12
11.5
Example: To Configure Heating and Cooling
Enter configuration level as described. Then:-
Do This
The Display You
Should See
Additional Notes
1.
Press
as many times as necessary
to select ‘CTRL’
2.
Press
to scroll to ‘CTRLH’
3.
Press
▲
or
▼
to select the
Heating Type
Heating Type choices are:-
Pid
PID (3 term) control
on.of
On/Off control
oFF
No heating output configured
4.
Press
to select ‘CTRL.C’
5.
Press
▲
or
▼
to select the
Cooling Type
Cooling Type choices are:-
oFF
No cooling output configured
PId
PID (3 term) control
on.of
On/Off control
6.
Press
to select ‘CTRL.A’
7.
Press
▲
or
▼
to ‘
rev
’
Control Action choices are:-
rev
Reverse - heating control
Dir
Direct - cooling only control
8.
Press
to scroll to ‘PB.UNT’
9.
Press
▲
or
▼
to choose units
Proportional Band Units choices are:-
EnG
Engineering units
Perc
Percentage
10.
Continue to select parameters using
for example ‘OP.HI’
11.
Press
▲
or
▼
to change their
values
When
PID control
is selected, this places a limit on the
output demand from the PID which can be applied to
the heating circuit.
‘
O P.LO
’ can be set up in the same way if required.
If
on/off control
is selected these parameters do not
apply. They are replaced by ‘HYST.H’ and ‘HYST.L’ to set
the difference between the output switching off to
switching on.
Summary of Contents for XST-2-0-12-1V1-E28
Page 16: ...12 FURNACE TROUBLE SHOOTING ...
Page 27: ...ɸ ...
Page 28: ...ɸ ...
Page 29: ......
Page 30: ......
Page 31: ...3216 3208 3204 User Manual 3200 Range Process Controller HA028651 11 Aug 2012 ...
Page 170: ...User Manual 3200 Series 138 Part No HA028651 Issue 11 0 July 12 21 Certificate of Conformity ...
Page 171: ......
Page 173: ...Model 2416 Process Controller User Manual Part No HA025041_12 Date August 2014 ...
Page 174: ...This page is intentionally blank ...
Page 259: ...This page is intentionally blank ...