3200 Series
User Manual
Part No HA028651 Issue 11.0 July-12 53
10.2
Example: To Set Ramp Rate
This is available in Level 3.
Do This
The Display You
Should See
Additional Notes
1.
Press
as many times as necessary
to select
‘SETPOINT LIST’
2.
Press
as many times as necessary
to scroll to ‘SP1’
3.
Press
▲
or
▼
to adjust setpoint 1
This step can be repeated for the lower setpoint limit
‘
SP.LO
’
4.
Press
to scroll to ‘SP2’
5.
Press
▲
or
▼
to adjust setpoint 2
6.
Press
as many times as necessary
to scroll to ‘SP.RAT’
7.
Press
▲
or
▼
to set the rate at
which you require the setpoint to
change
Whenever the setpoint is changed, the controller will
ramp from its current setpoint to the new value at the
rate set in units per second, minute or hours as set by
the ‘RAMPU’ parameter.
It will also change at the same rate when switching
between SP2 and SP1 (but not between SP1 and SP2)
The setpoint rate resolution is generally one decimal
point more than setpoint/PV resolution
73.00
sp 1
50.00
sp 2
6.000
S p. ra t
Summary of Contents for XST-2-0-12-1V1-E28
Page 16: ...12 FURNACE TROUBLE SHOOTING ...
Page 27: ...ɸ ...
Page 28: ...ɸ ...
Page 29: ......
Page 30: ......
Page 31: ...3216 3208 3204 User Manual 3200 Range Process Controller HA028651 11 Aug 2012 ...
Page 170: ...User Manual 3200 Series 138 Part No HA028651 Issue 11 0 July 12 21 Certificate of Conformity ...
Page 171: ......
Page 173: ...Model 2416 Process Controller User Manual Part No HA025041_12 Date August 2014 ...
Page 174: ...This page is intentionally blank ...
Page 259: ...This page is intentionally blank ...