The range hood is designed and manufactured according to DS/
EN 60335-1.
•
This range hood is only for use in private house holdings, if used
for other purposes the warranty will be repealed.
•
Installation must be performed by a skilled electrician in
accordance with the specifications given by Thermex Scandinavia
A/S (Thermex) and legislation in force.
•
Thermex disclaims all responsibility in regards to damages caused
by wrong installation, mounting or use.
BEFORE MOUNTING/COMMISSIONING
•
Inspect the range hood for transport damages, flaws and defects
immediately after the receipt.
•
Transport damages must be filed to the haulage contractor and
Thermex immediately after the receipt.
•
Flaws and defects must be filed to Thermex within 8 days the
receipt, and not later than mounting/commissioning.
MOUNTING
•
The range hood is intended for working at 230 Volt ±10%~ 50 HZ
in referring to EN 50160.
•
Connect the hood with the attached plug. NOTE: The hood MUST
have earth if the plug has an earth connection.
•
For models with external motor applies that NOT to use common
zero by installing the hood and motor, as this will affect the
control.
•
It MUST be ensured that the motor can be used with the selected
range hood when using an external motor from another supplier.
Otherwise the warranty no longer apply.
•
Do not plug in the range hood until the mounting is complete.
•
The air must not be discharged from the hood into a pipe used for
extraction from devices using gas or other fuels. Such devices
must have a separate vent.
•
The national legislation on air emissions must be observed.
•
Always use the original dimension of the vent. By reducing the
dimension of the vent, the performance will be reduced and the
sound level will be increased.
•
The vent to the open air, must be as short as possible in order to
get the greatest possible capacity of the range hood.
•
The number of bends on the vent ought to be minimised, to gain
the greatest possible capacity of the range hood.
•
Thermex recommends to always use sound and condensation
insulated vent hose at the carrying through in unheated spaces.
•
Thermex recommends that there is used for a muffler to
minimize the noise level when using flexible hose.
•
Using the flexible hose must always ensure that this is fully
extended to minimize air resistance and thereby achieve
maximum absorbency.
•
Different materials takes different rawlplugs and screws. Use
rawlplugs and screws intented for the material the range hood is
to be mounted in.
•
If the instructions for the installation of screws and fittings are
not followed, it may result in electrical shock.
•
The minimum distance to gas stoves from the burner's edge to
the underside of the hood MUST be minimum 65 cm in accor-
dance with EN 60335-2-31.
•
Thermex recommends that the space between the lower edge of
the range hood and cooker is between 50 cm and 70 cm, valid for
all cabinet range hoods, islands and wall mounted range hoods.
•
Always control the stated minimum distance between cooker
and range hood in the manual for the cooker. If the manual for
the cooker states a greater distance than what Thermex
recommends the manual for the cooker MUST be followed.
•
Thermex recommends that the space between cooker and range
hood does not exceed 3 meters for range hoods integrated in the
ceiling