The room thermostat can be connected to the main board by removing the bridge shown in Figure
12 and connec ng the cables of the room thermostat to these terminals. This connec on is
suitable for both simple type and digital type room thermostats.
12 . ELECTRIC SCHEME AND ROOM THERMOSTAT
Figure 12
Room thermostat
connec on
To use a room thermostat capable of controlling all func ons of the boiler including domes c hot
water produc on, contact with your authorised service agency. Such room thermostats may
provide internet connec on and remote access may be made. If required, you may control the
appliance through a computer or smart phones and tablets that provide required features.
OPENTHETM ® REMOTE CONTROL (OPTIONAL)
The remote control is designed for temperature
management of any type environment Through
this communica on protocol all func ons of the
boiler can be controlled by the remote control:
control range covers from opera ng mode
(OFF/SUMMER/WINTER) ) selec on to domes c
hot water / central hea ng flow temperature
adjustments and displaying diagnos c codes of
most common errors as well as restar ng the
appliance.