7
d.
On the chimney walls
11. FLUE CONNECTION
a.
Building stairwells,
b.
Building aisles,
When connec ng the flue, the flue gas accessories supplied by the manufactured must be used.
When selec ng the loca on of the boiler the posi on of flue gas connec on and flue terminal
should be considered. For flue connec on the requirements set forth by the local authori es and
gas distribu ng company must be observed.
Flue connec on must not be made to:
c.
Light-wells,
e.
Balconies
The followings must be observed when making flue connec on:
b.
Minimum ver cal distance above the ground should be 0,3 m and in places where there is an
impact risk the flue terminal must be covered with a wire net.
c.
When the flue terminal is extended off the wall it must extend minimum 18 mm outside the wall.
f.
Elevator sha s
a.
Flue terminal ver cal distance to eaves and roof coverings should be minimum 1,5 m from the
top and should also extend further from such eaves and roof coverings.
d.
Horizontally connected flue connec ons must be installed with 1% downward slope.