30
ENGLISH
INSTALLER
INSTALLER
Removing the hinge assembly "B"
System A
- First ensure that the side safety bolt (2) is tight and then
remove the main fixing bolt (1)
- With the door open, remove the hinge assembly ‘B’
(bushing, bolt, and washer) opposite the pivot side of
the door.
axis of
door rotation
B
Earth connection
A terminal is provided on the front boiler head to connect the
boiler body to an efficient earth system.
Proceed as follows.
- Unscrew the nut and washer (1) from the earth terminal
- Attach the earth cable’s eye connector (2) to the termi-
nal. (Make sure that the cable is of adequate size and
complies with legislation in the country of installation)
- Fit the nut and washer (1) to the earth terminal and
tighten the nut
- Connect the other end of the cable to the system’s earth
bar.
(*)
(**)
1
2
1
(**)
M6x30 brass
b
Another hole (*) in the left side of the boiler head can
also be used to earth the appliance. If you wish to use
this hole for the earth connection, remove the terminal
fittings from the right of the head and move them to the
left earthing point.