the  second  heating  stage  will  be  received.  The  target 
temperature will immediately start increasing. 

 

 
N.B. 

If  the  system  is  in  “boost”  most  of  the  time,  this 

means  that  the  boiler  target  parameter  established 
during  “Setting  procedure”  would  be  too  low  for  the 
heating system on which the unit is applied. This boiler 
target  could  simply  be  gradually  increased  by  pressing 
the  +  button  or  by  re-setting  the  operating  parameters 
using the tool menus 

The Boost menu can be cancelled by selecting “OFF” in 
the Boost menu.  

 
4.11 OPERATION IN AUTOMATIC TRANSFER 
MODE: 

In automatic transfer mode, the display will indicate that 
this mode is active in showing the icon  

 

If it is not shown, check the position of the switch located 
at the back of the controller. 

It must be set to “Bi-Energ” 

position. 
N.B.  The  controller  will  have  to  be  reset to  register  the 
new  mode  of  operation.  Just  turn  the  power  OFF  and 
back ON to the unit. 
 

Operation  in  automatic  transfer  mode  with  Electric 
Boiler 

When the authorisation signal to operate in electricity is 
received, (closed contact between 

E

& E

2

), the following 

icons will be shown. 
 

 

The  circulating  pump  and  the  heating  elements  will  be 
activated  according  to  the  operating  parameters 
established earlier. 
 

Operation 

in 

automatic 

transfer 

mode 

with 

Renewable energy source 

When  the  authorisation  signal  will  be  absent  (open 
contact  between 

E

1

&E

2

),  the  following  icons  will  be 

shown. 

                                    

 

 

Upon  reception  of  a  heat  demand  on  terminals 

R  W

  of 

the  ECO  ULTRA  boiler,  terminals 

P

1

&P

2

  will  be 

energized at 120volts and the pump will be activated. At 
the  same  time,  the  contact  will  close  on  the  “

AUX”

 

terminals  to activate  the  auxiliary  boiler.  This  boiler  will 
be  activated  only  when  there  will  be  a  heat  demand  to 
the 

R  W

  terminals  and  when  the  auxiliary  boiler 

temperature  will  be  lower  than  the  settings  of  its  own 
temperature controls.  
 

Using the 

"

AUX

"

 terminals on the ECO ULTRA to allow 

the start-up of the renewable energy source, you operate 
either  with  the  renewable  energy  source  or  with 
electricity.  
 
It is also possible to allow the renewable energy source 
to be operated according to its own controls at all times 
(do not use the contact of the "

AUX

" terminals) and when 

the latter is not sufficient to the request, (closed contact 
between 

E1 & E2

) the heating elements will be activated 

according  to  the  operating  parameters  established 
previously.

 

 

Manual  selection  for  the  electricity  or  renewable 
energy source. 

If  the  user  wishes  to  manually  select  the  electricity  or 
renewable energy source, it can be done in following the 
sequence below: 

o

 

Push  on  the 

button  for  6  sec.  and  the 

following icons will appear 

 

 
The  selection  of  the  dual-energy  or  electric  only  or 
auxiliary boiler only is made with the + - button. Once the 
selection has been made it will be registered by pressing 
the 

or by waiting for 5sec. 

 
If  the  electricity  only  or  auxiliary  boiler  only  has  been 

selected, the corresponding icon and the 

 icons will 

blink  to  advise  the  user  that  an  unusual  heating  mode 
has been selected. 
 

80F

27C

70F

21C

60F

15C

50F

10C

10F

-12C

40F

4C

30F

0C

20F

-7C

0F

-17C

-10F

-23C

-20F

-29C

70F/21C

80F/27C

100F/-38C

90F/32C

110F/43C

120F/49C

130F/54C

Température ext.  / Outdoor temperature 

T

e

m

p

d

e

 c

o

n

s

ig

n

e

 /

 T

a

rg

e

te

m

p

NOR

MAL

BOO

ST

HAUSSE AUTOMATIQUE DU POINT DE CONSIGNE 

« BOOST »

AUTOMATIC INCREASE OF TARGET TEMPERATURE

Summary of Contents for ECO ULTRA 12

Page 1: ...oiler in order to ensure your full satisfaction It is imperative that all persons who are expected to install operate or adjust this boiler read the instructions carefully Any questions regarding the operation maintenance service or warranty of this water heater should be directed to the dealer or distributor you purchased it from When all installation steps have been completed replace this instal...

Page 2: ...power supply 13 3 7 2 Heating pump wiring 13 3 7 3 Outdoor temperature sensor 13 3 7 4 Room thermostat wiring 13 3 7 5 Automatic transfer mode wiring 14 3 8 WIRING DIAGRAMS 16 Section 4 ADJUSTMENT OF THE CONTROLLER 18 4 1 INTRODUCTION 18 4 2 DISPLAYED INFORMATION 18 4 3 OPERATION OF THE INTERFACE 19 4 4 OPERATION IN FIXED BOILER TEMPERATURE SET POINT 19 4 5 OPERATION WITH OUTDOOR RESET 19 4 6 PURG...

Page 3: ... 1 00 150 294 21 8 29 2 x 4 5 kW 4 x 5 kW 104 120 1 00 175 1Electrical supply 120 240V or 120 208V single phase L1 N L2 with three 90 C conductors or two conductors L1 L2 if the boiler does not require power to a 120 VAC pump or accessories 2Add the amperage of the circulating pump and other external accessories if they are connected to the boiler max 5A 3A higher cable size could be required In a...

Page 4: ...ectrical mode or automatic transfer mode For both modes it is recommended to use the outdoor sensor supplied with the equipment The outdoor sensor allows the boiler water temperature to be modulated according to the outside temperature It also makes it possible to stop the heating of the electric elements when the outside temperature exceeds a certain temperature The use of these functions makes i...

Page 5: ...where instructions in this manual differ from local or national codes the local or national codes take precedence 2 2 CORROSIVE ATMOSPHERE The electric boiler should not be located near an air supply containing halogenated hydrocarbons or high humidity The limited warranty is voided when failure of the water heater is due to a corrosive atmosphere 2 3 SHIPMENT INSPECTION Inspect the electric boile...

Page 6: ...odels sale in USA have a second limit device manually re settable set at 227 F 108 C If the heating distribution system on which the boiler is installed requires a high limit controller having a lower setting this controller will be added to the system and connected in series with the factory installed limit control 3 2 LOCATION The ECO ULTRA boiler should be installed in a clean dry location Long...

Page 7: ...ENTS Figures 2 and 3 show various components of the ECO ULTRA electric boiler Figures 4 and 6 show some installation drawings of the boiler in the autonomous electrical mode Figures 5 7 and 8 show some installation drawings of the boiler in the automatic transfer mode Figure 2 Components identification and location top right side view Pressure relief valve 30 psi Automatic air vent Temperature and...

Page 8: ... 2017 Page 8 Figure 3 Components identification and location left side view Adjustable feet UltraSmart controller Heating elements Heating return Model 50 1 NPTM Model 70 1 NPTM Electrical components mounting panel Drain valve Heating supply Model 50 1 NPTM Model 70 1 NPTM ...

Page 9: ...perature indicator Drain valve Automatic air vent Air seperaor Service valve Pressure relief valve Union Expansion tank Pressure regulator Thermostatic mixing valve Chaudière au bois ECO ULTRA Back flow preventor TT 120 V EE ECO ULTRA INSTALLED WITH WOOD BOILER AUTONOMOUS ELECTRICAL MODE Legend Outdoor sensor Circulating pump Room thermostat Pressure and temperature indicator Drain valve Automatic...

Page 10: ...Pressure and temperature indicator Drain valve Automatic air vent Air seperaor Service valve Pressure relief valve Union Expansion tank Pressure regulator Thermostatic mixing valve Air to water heat pump ECO ULTRA Back flow preventor EE ECO ULTRA INSTALLED WITH AIR TO WATER HEAT PUMP AUTOMATIC TRANSFER MODE Legend Outdoor sensor Circulating pump Room thermostat Pressure and temperature indicator D...

Page 11: ...ECO ULTRA INSTALLED WITH AIR TO WATER HEAT PUMP AUTOMATIC TRANSFER MODE Legend Outdoor sensor Circulating pump Room thermostat Pressure and temperature indicator Drain valve Éliminateur d air automatique Air seperaor Service valve Pressure relief valve Union Expansion tank Pressure regulator Thermostatic mixing valve Air to water heat pump ECO ULTRA Back flow preventor Cooling system EE ...

Page 12: ...ing NEVER cap or plug a pressure relief valve outlet The pressure relief valve is a safety apparatus and preventing its proper operation may cause death injury or property damage 3 6 4 Expansion tank When operating the ECO ULTRA and the heating system pressure will vary between 83 kPa and 193 kPa 12 psi to 28 psi The operating pressure is affected by the type of heating system and the size of the ...

Page 13: ...o the boiler electric panel PP terminals The boiler control will operate the pump as soon as a heat demand is signalled by the space thermostat 3 7 3 Outdoor temperature sensor If you want the boiler target temperature to modulate according to the outdoor temperature when the outdoor temp will get colder the target temperature will get higher The supplied outdoor sensor will have to be connected t...

Page 14: ...the energy source selected To allow the operation in automatic transfer mode Open the front access panel to the boiler electric compartment Remove the screw at the bottom of the controller raise the upper section of the controller You will see a switch at the back of the controller having two positions ELECT and Bi Energ Position the switch at Bi Energ see fig 9 Install a 2 wire 18ga cable between...

Page 15: ...o allow the renewable energy source to be operated according to its own controls at all times do not use the ECO ULTRA contact of the AUX terminals and when the main renewable energy source is not sufficient to the request closed contact between E1 E2 the heating elements will be activated according to the operating parameters of the controller External signal ...

Page 16: ...ECO ULTRA Electric Boiler Installation Use and Care Manual Revision June 2017 Page 16 3 8 WIRING DIAGRAMS ...

Page 17: ...ECO ULTRA Electric Boiler Installation Use and Care Manual Revision June 2017 Page 17 ...

Page 18: ...he water of the heating system flows directly from the boiler to the heating distribution system Standard parallel Piping system Two operation modes are then offered Fixed boiler temperature set point the outdoor sensor shall not be installed Or Outdoor reset 4 2 DISPLAYED INFORMATION The electronic control uses an LCD display to make all adjustments and to visualize the operation of the system Fi...

Page 19: ...ture of the boiler near the selected target temperature A rotation of the stages based on an equal time period of operation is provided N B The supplied outdoor temperature sensor shall not be connected before applying the electrical power to the unit 4 5 OPERATION WITH OUTDOOR RESET For installation where the boiler target temperature shall modulate in relation to the outdoor temperature when the...

Page 20: ...selected on systems equipped with motorised fast closing zone valves in order to prevent noise from water hammering 15 sec to 60 min delay where the pump will be kept running to enable the pump to circulate water into the system to equilibrate the heat in all the building ON The pump is in continuous operation Required on particular heating distribution systems 4 7 AUTOMATIC HEATING SHUT DOWN When...

Page 21: ...as they were established before the failure Table 5 below shows the presentation sequence of the menus Table 6 CONFIGURATION SEQUENCE OF THE MENU Press on the button for 2 seconds ITEM DESCRIPTION RANGE DEFAULT Choose the units the user prefers to work with F or C F Select the type of heating system on which the boiler will be installed Radiant Floor in concrete Radiant Floor between joists Cast i...

Page 22: ...ler temperature to recuperate Return to normal room temperature after thermostat s night set back program Three Boost operating options are available when the is pressed for 6 sec The icon will appear and the three options ON1 ON2 and OFF will be proposed Press the button to select The controller will register the selected item and will return to normal operation after 5 sec Operation in Boost Opt...

Page 23: ...120volts and the pump will be activated At the same time the contact will close on the AUX terminals to activate the auxiliary boiler This boiler will be activated only when there will be a heat demand to the R W terminals and when the auxiliary boiler temperature will be lower than the settings of its own temperature controls Using the AUX terminals on the ECO ULTRA to allow the start up of the r...

Page 24: ...r as explained earlier and set the purge delay of the pump from On to its normal operation setting The pump should stop 5 2 STARTUP INSPECTION Set the room thermostat ON to generate a heat demand The pump shall start The heating elements shall gradually come on and the boiler temperature will increase N B A rapid activation of all the elements and external components can be done by pressing simult...

Page 25: ...N Make sure that the power supply to the water heater has been turn off at the circuit breaker before attempting any work on the water heater Visual inspection of the water heater electrical cabinet Check for leaks at the heating elements sign of overheating of electrical components and wiring At the beginning of the heating season check for proper operation of the boiler controller circulating pu...

Page 26: ... located in the immersion well located at the top of the elect element compartment Check the resistance value ohms of the sensor It should correspond to the value shown on the table below otherwise it should be replaced Stage 2 is ON but not Stage 1 There is no problem A rotation of the stages is provided to allow an equal time of operation of the stages When stage 3 or 4 comes ON stage 1 or 2 com...

Page 27: ...k supply voltage to the boiler Boiler safety valve is leaking Pressure reading at the indicator shows a pressure above 28psi Pressure is below 28psi The pressure regulator on the distribution system is defective or the expansion tank is too small or defective Replace the safety valve Table 7 Resistance value of the outdoor sensor vs outdoor temperature Temperature Resistance Temperature Resistance...

Page 28: ...100 2PC5024 Transformer 208 240V x 24Vac ZEL400 20842440 40VA UltraSmart controller ZEL100 ULTRA Hi Limit automatic reset switch ZEL200 L6C732 Power Relay 24Vac ZEL100 24ACNO30 Fuse ZEL250 TDMIDJ5 2 poles contactor 24Vac ZEL100 2PC5024 Transformer 208 240V x 24Vac ZEL400 20842440 40VA UltraSmart controller ZEL100 ULTRA Hi Limit automatic reset switch ZEL200 L6C732 Power Relay 24Vac ZEL100 24ACNO30...

Page 29: ...0A24 Transformer 208 240V x 24Vac ZEL400 20842440 40VA UltraSmart controller ZEL100 ULTRA Hi Limit automatic reset switch ZEL200 L6C732 Power Relay 24Vac ZEL100 24ACNO30 Fuse ZEL250 TDMIDJ5 4 poles contactor 24Vac ZEL100 4P50A24 Transformer 208 240V x 24Vac ZEL400 20842440 40VA UltraSmart controller ZEL100 ULTRA Hi Limit automatic reset switch ZEL200 L6C732 Power Relay 24Vac ZEL100 24ACNO30 Fuse Z...

Page 30: ... Page 30 Figure 18 Electrical panel ECO ULTRA 27 29 kW 3 poles contactor 24Vac ZEL100 3P50A24 Transformer 208 240V x 24Vac ZEL400 20842440 40VA UltraSmart controller ZEL100 ULTRA Hi Limit automatic reset switch ZEL200 L6C732 Power Relay 24Vac ZEL100 24ACNO30 Fuse ZEL250 TDMIDJ5 ...

Page 31: ...ng is the lowest that satisfied the needs consistent with the application To find hot water temperature being delivered turn on a hot water faucet and place a thermometer in the hot water stream and read the thermometer The following chart details the relationship of water temperature and time with regard to scald injury and may be used as a guide in determining the safest water temperature for yo...

Page 32: ...ater must be installed in accordance with these instructions and must conform to local or in the absence of local codes with the current edition of the National Plumbing Code and the National Electric Code In any case where instructions in this manual differ from local or national codes the local or national codes take precedence The heat transfer medium must be water or other non toxic fluid havi...

Page 33: ...used Install shutoff ball valves for servicing convenience Use only clean copper or approved plastic pipe for water connections Local codes or regulations shall govern the exact type of material to be used To minimize heat loss during non draw periods a heat trap formed from piping can be used Insulate all pipes containing hot water especially in unheated areas Cap or plug unused connections If th...

Page 34: ... valve Éliminateur d air automatique Air seperator Service valve Pressure relief valve Union Expansion tank Pressure regulator Thermostatic mixing valve Air to water heat pump ECO ULTRA Back flow preventor Cooling system Safety valve Instantaneous water heater RA89 34 21 ECO ULTRA HEAT EXCHANGER OPTION INSTALLED WITH WOOD BOILER AUTOMATIC TRANSFER MODE Legend Outdoor sensor Circulating pump Room t...

Page 35: ...tch downward from the valve to allow complete draining by gravity of the relief valve and discharge line and be no smaller than the outlet of the valve The end of the discharge line should not be threaded or concealed and should be protected from freezing No valve of any type restriction or reducer coupling should be installed in the discharge line Local codes shall govern the installation of reli...

Page 36: ...t operation will result when the temperature setting is the lowest that satisfies the needs consistent with the application The maximum setting for the boiler water supply to the heater coil is 210 F The boiler supply temperature should be from 20 F up to 40 F higher than the domestic water temperature More exactly the boiler supply temperature should be higher than the domestic supply temperature...

Page 37: ... the Hot and Mixed temperature for proper operation To set the thermostatic mixing valve carefully open a hot water tap Protect yourself against the risk of scalding Use a thermometer and measure hot water temperature form the faucet Reduce or increase the hot water temperature by adjusting the valve knob to the proper position Lock the knob at the set temperature Refer to the valve manufacturer s...

Page 38: ...tion Must be manually operated to ensure safe and proper operation Make sure that the discharged water is directed to a suitable drain or some collection method and will not spray onto any person Use lever on the temperature pressure valve to open A steady discharge of hot water should be noticed After releasing this lever the safety relief valve should close and fully shut off this flow If the te...

Page 39: ...eaker and reset Check power supply Scale build up in thermostatic mixing valve or coil If boiler circulator and TURBOMAX temperature controls are operating satisfactory the coil system may have scale coating Clean the coil as described in the Maintenance section Water at faucet is too hot Thermostatic mixing valve temperature setting is too high Lower the temperature setting of the mixing valve Co...

Page 40: ... repair maintenance and or usage that are not done in conformity with the manufacturer s installation manual or B Defects or malfunctions resulting from installation maintenance or repair that are not done in accordance with regulations in force or C Defects or malfunctions resulting from improper installation maintenance or repair done carelessly or resulting from consumer damage improper mainten...

Reviews: