ECO ULTRA Electric Boiler
Installation, Use and Care Manual
(Revision June 2017)
, Page
23.
the second heating stage will be received. The target
temperature will immediately start increasing.
N.B.
If the system is in “boost” most of the time, this
means that the boiler target parameter established
during “Setting procedure” would be too low for the
heating system on which the unit is applied. This boiler
target could simply be gradually increased by pressing
the + button or by re-setting the operating parameters
using the tool menus
.
The Boost menu can be cancelled by selecting “OFF” in
the Boost menu.
4.11 OPERATION IN AUTOMATIC TRANSFER
MODE:
In automatic transfer mode, the display will indicate that
this mode is active in showing the icon
If it is not shown, check the position of the switch located
at the back of the controller.
It must be set to “Bi-Energ”
position.
N.B. The controller will have to be reset to register the
new mode of operation. Just turn the power OFF and
back ON to the unit.
Operation in automatic transfer mode with Electric
Boiler
When the authorisation signal to operate in electricity is
received, (closed contact between
E
1
& E
2
), the following
icons will be shown.
The circulating pump and the heating elements will be
activated according to the operating parameters
established earlier.
Operation
in
automatic
transfer
mode
with
Renewable energy source
When the authorisation signal will be absent (open
contact between
E
1
&E
2
), the following icons will be
shown.
Upon reception of a heat demand on terminals
R W
of
the ECO ULTRA boiler, terminals
P
1
&P
2
will be
energized at 120volts and the pump will be activated. At
the same time, the contact will close on the “
AUX”
terminals to activate the auxiliary boiler. This boiler will
be activated only when there will be a heat demand to
the
R W
terminals and when the auxiliary boiler
temperature will be lower than the settings of its own
temperature controls.
Using the
"
AUX
"
terminals on the ECO ULTRA to allow
the start-up of the renewable energy source, you operate
either with the renewable energy source or with
electricity.
It is also possible to allow the renewable energy source
to be operated according to its own controls at all times
(do not use the contact of the "
AUX
" terminals) and when
the latter is not sufficient to the request, (closed contact
between
E1 & E2
) the heating elements will be activated
according to the operating parameters established
previously.
Manual selection for the electricity or renewable
energy source.
If the user wishes to manually select the electricity or
renewable energy source, it can be done in following the
sequence below:
o
Push on the
button for 6 sec. and the
following icons will appear
The selection of the dual-energy or electric only or
auxiliary boiler only is made with the + - button. Once the
selection has been made it will be registered by pressing
the
or by waiting for 5sec.
If the electricity only or auxiliary boiler only has been
selected, the corresponding icon and the
icons will
blink to advise the user that an unusual heating mode
has been selected.
80F
27C
70F
21C
60F
15C
50F
10C
10F
-12C
40F
4C
30F
0C
20F
-7C
0F
-17C
-10F
-23C
-20F
-29C
70F/21C
80F/27C
100F/-38C
90F/32C
110F/43C
120F/49C
130F/54C
Température ext. / Outdoor temperature
T
e
m
p
.
d
e
c
o
n
s
ig
n
e
/
T
a
rg
e
t
te
m
p
.
NOR
MAL
BOO
ST
HAUSSE AUTOMATIQUE DU POINT DE CONSIGNE
« BOOST »
AUTOMATIC INCREASE OF TARGET TEMPERATURE