Appendix F
INSTALLER/SERVICEMAN
Model Number S-125 S-135
Burner Type Riello Riello
Burner Model F5 F5
Nozzle Type 1.00 60A 1.10 60A
Pump Pressure PSI 150 150
Head/Pin Position 2.5 3.5
Air Band N/A N/A
Air Shutter 4.5 4.5
Draft Over Fire -0.02" -0.02"
Draft In Stack -0.05" -0.05"
CO2 Reading 10-11.5 10-11.5
Smoke Reading ZERO ZERO
NOTICE
Above settings are approximate. Final adjustments to be made
with proper test equipment. Be sure all oil lines are air free and
the use of flare fittings is recommended. See installation/service
manual for detailed information.
________________________
________________________
________________________
________________________
________________________
________________________
________________________
________________________
________________________
________________________
INSTALLER/SERVICEMAN
Model Number S-125 S-135
Burner Type Carlin Carlin
Burner Model EZ-1 EZ-1
Nozzle Type 1.00 60A 1.10 60A
Pump Pressure PSI 140 140
Head/Pin Position 110-125 135-150
Air Band 1.25 1.35
Air Shutter N/A N/A
Draft Over Fire -0.02" -0.02"
Draft In Stack -0.05" -0.05"
CO2 Reading 10-11.5 10-11.5
Smoke Reading ZERO ZERO
NOTICE
Above settings are approximate. Final adjustments to be made
with proper test equipment. Be sure all oil lines are air free and
the use of flare fittings is recommended. See installation/service
manual for detailed information.
________________________
________________________
________________________
________________________
________________________
________________________
________________________
________________________
________________________
________________________
INSTALLER/SERVICEMAN
Model Number S-125 S-135
Burner Type Beckett Beckett
Burner Model AFG AFG
Nozzle Type 1.00 80A 1.10 80A
Pump Pressure PSI 140 140
Head/Pin Position F-12 F-12
Air Band CLOSED 1
Air Shutter 10 10
Draft Over Fire -0.02" -0.02"
Draft In Stack -0.05" -0.05"
CO2 Reading 10-11.5 10-11.5
Smoke Reading ZERO ZERO
NOTICE
Above settings are approximate. Final adjustments to be made
with proper test equipment. Be sure all oil lines are air free and
the use of flare fittings is recommended. See installation/service
manual for detailed information.
________________________
________________________
________________________
________________________
________________________
________________________
________________________
________________________
________________________
________________________