Thermo Dynamic water heater & central heating booster  
 

www.elitetdch.com

   ELITE TDCH  Aug 2014v3                                   Page 

20

 of 

26

 

 

Trouble shooting cont. 
 
 

Water escaping from the 
tank 

Codensation 

Check that there is no blockage in the condensate tray or 
condensate drip hose 

Water leak 

Check that none of the piping / connexions are leaking 
Check the pressure and temperature relief valve 
discharge is not causing the water leak 

Compressor working 
intermitantly 

Power source 

Check eletrical plug is in the socket correctly 
Cable is not in tension 

 

Drip tray and hose inspection clearing procedure 

 

1.  Switch off electrical power supply to the unit 
2.  Remove the four retaining screws in the top of the unit 
3.  Remove lid 
4.  Inspect the drip tray to see if there is excess water flowing over the tray 
5.  If so remove the drip pipe connexion from the rear of the unit ( use a container to catch 

any water) Fig A 

6.  If the drip tray drains then there is a blockage in the drip pipe, call your installer 
7.  If the tray does not drain  there is a blockage in the drip tray or internal drip pipe Fig B 
8.  This can be cleared by inserting a wire rod e.g.a wire coat hanger ,into the internal drip 

pipe and out through the tray outlet Fig C 

9.  Remove any debris. 
10. Re install drip pipe connector 
11. Re install lid and attach with the four screws 
12. Switch unit back on. 

 

 
 

 External drip pipe connextion Fig A 

 
 
 

Summary of Contents for ELITE TDCH

Page 1: ...Thermo Dynamic water heater central heating booster www elitetdch com ELITE TDCH Aug 2014v3 Page 1 of 26 USER MANUAL ELITE TDCH Installation Instructions and User Manual ...

Page 2: ...CAL CONNECTIONS 10 4 3 FILLING THE ACCUMULATOR 11 4 4 TURNING THE SYSTEM ON 11 5 USAGE RULES 12 5 1 TEMPERATURE ADJUSTMENT 12 5 2 ELECTRICAL RESISTANCE 13 6 MAINTENANCE REPAIR AND CLEANING 14 7 TROUBLESHOOTING 15 8 PREVENTION OF ISSUES 17 NOTES TO END USER THIS UNIT SHOULD ONLY BE INSTALLED BY QUALIFIED PERSONNEL IF AFTER INSTALLATION THE UNIT DEVELOPES ANY FAULTS CONTACT YOUR INSTALLER Installer ...

Page 3: ...ge 3 of 26 For any warranty questions contact the manufacturer Hidrodinamica Solar S L Ave De Los Labrodores 5 Local 28760 Tres Cantos Madrid Spain Tel 00 91 804 2612 Email jchacon energypanel es To avoid injury as well as the damaging the TDCH unit the following instructions should be followed ...

Page 4: ...om ELITE TDCH Aug 2014v3 Page 4 of 26 The TDCH is a thermo dynamic sytem based on air source heat pump using ambient room air which is then forced through a heat exchanger and condenser using refrigerent fluid This is all contained in a compact easy to install housing ...

Page 5: ...Thermo Dynamic water heater central heating booster www elitetdch com ELITE TDCH Aug 2014v3 Page 5 of 26 ...

Page 6: ... heater central heating booster www elitetdch com ELITE TDCH Aug 2014v3 Page 6 of 26 1 Compressor 2 Tank 3 Drum 4 Dehydrator 5 Expansion Valve 6 Ventilator 7 Condenser coil externa 8 Evaporator 9 CH booster coil internal 9 ...

Page 7: ...Thermo Dynamic water heater central heating booster www elitetdch com ELITE TDCH Aug 2014v3 Page 7 of 26 250 litres tank A 176 cm B 59 cm ...

Page 8: ...eating booster www elitetdch com ELITE TDCH Aug 2014v3 Page 8 of 26 10 Hot Water Outlet 11 Electrical Connection 12 Cold Water Inlet 13 Immerser coil 14 Heat exchange drip line 15 CH flow 16 Press Temp reducing outlet 17 CH return 15 16 17 ...

Page 9: ...d to Item 12 2 Hot water feed Item 10 3 Pressure temperature reducing valve to Item 16 this then connected to overflow 4 Heat exchange drip line connected down stream of P T overflow 3 5 Central heating flow to Item 15 6 Central heating return to Item 17 7 Pump and timer installed in Central Heating outlet 8 Plug in unit 9 Plug in timer pump 10 Check that compressor tray and drip line are free fro...

Page 10: ...Thermo Dynamic water heater central heating booster www elitetdch com ELITE TDCH Aug 2014v3 Page 10 of 26 Tank factory tested to 10 bar All connexions BSP ...

Page 11: ...out The installation should be carried out as detailed below Check that there is sufficient space for the unit see Fig 4 Check that there is sufficient space to hook up the pipework and electrics The unit must be transported vertically The unit must be installed vertically Check that the setting area in strong enough to take the units weight a 250 litre unit weighs approx 300 Kgs when full of wate...

Page 12: ...ks by drawing ambient air in extracting the heat and expelling cold air out at the rear of the unit It is best pactice to situate the unit next to an outside wall and and fit ducting to direct the cold air to the outside of the building Hot air drawn in through top of unit and cold air expelled at rear through wall ducting ...

Page 13: ... rated to 6 bar on the cold water feed side and a safety valve is supplied see Fig 5 and should be installed It is recommended that an expansion vessel tank is fitted on the cold water outlet side The current plumbing regulations should be referred to when fitting the expansion vessel 17 is located on the rear of the unit see Page 8 ...

Page 14: ...Thermo Dynamic water heater central heating booster www elitetdch com ELITE TDCH Aug 2014v3 Page 14 of 26 ...

Page 15: ...Immerser Coil Filling the tank After the pipework for the tank and the CH coil have been fitted Fill the tank by opening the cold water feed at the bottom of the unit See page 8 allow the tank to fill and monitor the hot water outlet for water returns Close the cold water feed and hook the hot water outlet to the hot water system ...

Page 16: ...Thermo Dynamic water heater central heating booster www elitetdch com ELITE TDCH Aug 2014v3 Page 16 of 26 ...

Page 17: ... a 2 K watt immerser coil situated at the back of the unit this can be switched on manually maximum temperature is set at 70 deg C the switch is on the front of the cabinet see Fig 7 resistance switch NOTE To activate the immerser coil both the thermodynamic and the immerser coil switches must be in the on position Immerser Coil ...

Page 18: ...Thermo Dynamic water heater central heating booster www elitetdch com ELITE TDCH Aug 2014v3 Page 18 of 26 ...

Page 19: ...Thermo Dynamic water heater central heating booster www elitetdch com ELITE TDCH Aug 2014v3 Page 19 of 26 ...

Page 20: ...h off electrical power supply to the unit 2 Remove the four retaining screws in the top of the unit 3 Remove lid 4 Inspect the drip tray to see if there is excess water flowing over the tray 5 If so remove the drip pipe connexion from the rear of the unit use a container to catch any water Fig A 6 If the drip tray drains then there is a blockage in the drip pipe call your installer 7 If the tray d...

Page 21: ...Thermo Dynamic water heater central heating booster www elitetdch com ELITE TDCH Aug 2014v3 Page 21 of 26 Fig B Fig C Drip Tray Internal drip pipe Cleaning rod inserted ...

Page 22: ...Thermo Dynamic water heater central heating booster www elitetdch com ELITE TDCH Aug 2014v3 Page 22 of 26 ...

Page 23: ... equals 40 V calories The energy saving is the difference between X Y 9 1 Connecting the TDCH booster After the TDCH water heater is connected to the drawn hot water circuit The central heating booster coil is connected to a WET CH system Standard or Combi in the case of a combi boiler the drawn hot water should be switched off When the booster coil is connected to the CH sytem the TDCH acts like ...

Page 24: ...s up but uses less fuel to reach operating temperature 18 When the boiler reaches operating temperature close the TDCH pump manually or by insertation of a thermastaically controlled switch optional 19 Set the timer to come on a 1 hour before the boiler start up time b hour after the boiler start up time The hot water setting is 55 Deg C The temeprature can be raised to 70 Deg C for the eliminatio...

Page 25: ...Thermo Dynamic water heater central heating booster www elitetdch com ELITE TDCH Aug 2014v3 Page 25 of 26 If in any doubt please refer to And this paragraph in particular ...

Page 26: ...Thermo Dynamic water heater central heating booster www elitetdch com ELITE TDCH Aug 2014v3 Page 26 of 26 Fig 7 ...

Reviews: