background image

Instruction Manual

Savant SPD111V

SpeedVac  Concentrator

197-3001-00 Rev. C

®

®

Summary of Contents for Savant SPD111V

Page 1: ...Instruction Manual Savant SPD111V SpeedVac Concentrator 197 3001 00 Rev C ...

Page 2: ...ce Page 6 0 Maintenance Service 8 Section Specifications Page 7 0 Specifications Warranty 9 Appendix 1 Additional SPD111V System Set ups 10 Disclaimer All statements information and data given herein are believed to be accurate and reliable but are presented without guarantee or respon sibility of any kind expressed or implied Statements or suggestions concerning possible use of our products are m...

Page 3: ...Skid Vibration 6 Right Side Panel 7 Chamber View Window 8 Vacuum Port 9 AC Socket 10 Main On Off Switch 11 Manual Cover Lock Release 12 Rear Access Panel 1 2 3 4 5 6 12 8 9 10 11 7 Figure 1 Front View Figure 2 Side View Figure 3 Back View 1 0 Overview of the SPD111V Unit Fig 1 Fig 2 Fig 3 1 ...

Page 4: ...igure 4 4 Vacuum clamps must be put on vacuum ports of pump and SPD unit See item 8 on Figure 2 and Figure 4 5 If being hooked up to existing system simply attach vacuum tubing to port on side of unit See item 8 figure 2 vacuum port CAUTION Cold trap should be in line between the vacuum source and the SPD Unit RVT4104 Refrigerated VaporTrap VLP Vacuum Pump SPD111V SpeedVac Concentrator 2 1 2 HOW T...

Page 5: ...modified 4 MODIFY SETPOINT UP DOWN Modifies selected parameter 5 AUTO RUN Starts an automated run See page 5 6 MANUAL RUN Starts a manual run See page 4 7 STOP Terminates manual or auto run 8 VIEW Press to view Displays preset parameters during a run displays actual values when not running 9 TEMPERATURE DISPLAY GREEN DISPLAY Indicates set temperature or actual temperature during a run in C 10 TIME...

Page 6: ... and modify HEAT TIME to between 0 01and 9 59 hours or CCC for continual heating When the heat timer expires the heater will shut off no matter what the temperature setpoint is except if CCC 6 Press the MANUAL RUN button The cover locks and rotor starts turning The decimal point blinks and the time display begins counting up The temperature rises to the set temperature The HEAT TIME will count dow...

Page 7: ...he decimal point blinks The heat time is counting down use select button to view HEAT TIME The temperature rises in 1 C increments to the set temperature The SAV valve will actuate applying vacuum to the chamber c Press R C for radiant cover heat optional Press at any time to turn OFF and ON NOTE If the cover is not closed the display will show Lid and the run will not start d Once the time decrem...

Page 8: ...100mm 13 x 100mm 18 x 100mm 17 x 95 16 x 100 18 x 150 mm 15ml conical 16 x 120mm 50ml conical 28 x 115mm 50ml pear shaped flask 100ml pear shaped flask 12 x 32mm 12 x 40mm vials 20 x 47mm v vials 1 dram vials 15 x 45mm 4ml 20 x 60mm v vials 18 x 52mm mini scintillation vials 28 x 60mm scintillation vials Microplates Microplates Deepwell Microplates 40 64 120 100 40 100 20 40 72 10 32 8 6 10 6 8 4 ...

Page 9: ...ance with respect to your solvent choice please contact the Applications Support Specialists at Thermo 5 0 GUIDELINES FOR SOLVENT CHOICE Part I Solvents suited for the SPD111V unit Ethanol Methanol Water Acetonitrile Part II Solvents NOT suited for the SPD111V unit Methylene Chloride Chloroform Ethyl Acetate Hydrochloric Acid Trifluoroacetic Acid TFA Dimethyl Sulfoxide DMSO Part III All other solv...

Page 10: ...ays clean up any spills immediately using absorbent paper towels Always wear gloves when cleaning and dispose of paper towel in appropriate designated refuse containers 3 Replace chamber seal if cracked Part number is 197 6020 00 4 Outside of unit can be cleaned with dilute solution of soap and water 5 For any other maintenance or service issues or service problems please contact Thermo ...

Page 11: ...kmanship and does not cover incidental or consequential damages Warranty work is subject to our inspection of the unit No instruments equipment or accessories will be accepted without a Return Material Authorization RMA number issued by Thermo Costs of shipping the unit are not covered under warranty The warranty obliges you to follow the precautions in this manual It is the responsibility of the ...

Page 12: ...D SYSTEM SpeedVac Concentrator SPD111V UVS400 Universal Vacuum Source ANT100 Vacuum Tubing COMPONENT HIGH VACUUM SYSTEM Flexible Vacuum Tubing DVG50 SpeedVac Concentrator SPD111V RVT400 Cold Trap SCT120 Chemical Trap VLP120 Vacuum Pump Bleeder Valve Bleeder Valve ...

Page 13: ...SPD SERIES SPEEDVAC FAMILY SPD101B SPD111V SPD121P ...

Page 14: ... 1101 Fax 91 22 2778 1103 Bangaalore India 81 45 453 9122 Fax 81 45 453 9222 Yokohama City Japan International Sales Office Locations Bioscience Technologies Thermo Electron Corporation 866 9 THERMO 866 984 3766 Molecular Biology info molbio thermo com Sample Preparation info sampleprep thermo com New Labs newlabs thermo com Services services biosciencetech thermo com Laboratory Pipetting and Cons...

Reviews: