Refrigeration Service Operations
146
System Clean-up
Existing clean up devices such as suction line
filter P/N 204-498, adapters and manifold
P/N 204-500, and compressor oil filters may be
used if they are thoroughly cleaned and new filter
elements are installed. All standard compressor
oils must be removed from clean-up devices to
prevent contamination of R-404A systems.
Dangerous contamination will result if other
refrigerants or standard oils are introduced to
R-404A systems.
NOTE: For additional information on parts and
supplies, consult your local Thermo King dealer
and the Thermo King Tool Catalog.
Refrigerant Recovery
Present systems can be adapted to the recovery of
R-404A but should be dedicated to the recovery of
these refrigerants. Consult the manufacturer of
your recovery equipment for details.
Throttling Valve
Removal
1. Pump down the unit using the refrigerant
recovery system.
2. Front seat the suction service valve. Release
remaining pressure.
3. Remove the suction valve and line.
4. Unbolt and remove the throttling valve from
the unit.
Disassembly
1. Remove the piston end cap.
2. Remove the cotter pin from the castle nut and
remove the nut.
3. Remove the spring and piston.
4. Loosen all the bolts on bellows end cap.
5. Break the gasket free and remove the end cap.
6. Note the number of shims next to the cap.
These can be reused.
7. Remove bellows (discard).
8. Inspect all the parts (replace if excess wear is
found).
a. Piston and cap for wear (scuff marks)
b. Body for stripped threads
c. Bellows end cap for damage in pilot hole
NOTE: Bellows is normally replaced.
.
CAUTION: This end cap is under slight
spring pressure.
1.
Inspect Cap
2.
Inspect Spring
3.
Shims
Figure 168: Throttle Valve, Cap and Spring
1.
Inspect for Wear
Figure 169: Throttle Valve Piston
Summary of Contents for SPECTRUM TS 30 SR NAD
Page 4: ...4 ...
Page 10: ...Table of Contents 10 ...
Page 20: ...Safety Precautions 20 ...
Page 51: ...Unit Description 51 Figure 19 Front View Figure 20 Back View AJA1350 AJA1500 ...
Page 52: ...Unit Description 52 1 On Off Switch Figure 21 Side View 1 ...
Page 60: ...Unit Description 60 ...
Page 80: ...SPECTRUM TS Operation 80 ...
Page 90: ...Electrical Maintenance 90 ...
Page 100: ...Engine Maintenance 100 Figure 130 Early TK 3 95 Fuel and Oil System Components ...
Page 102: ...Engine Maintenance 102 Figure 131 Late TK 3 95 Fuel and Oil System Components ...
Page 104: ...Engine Maintenance 104 Figure 132 TK376 Fuel and Oil System Components ...
Page 136: ...Refrigeration Maintenance 136 ...
Page 156: ...Hilliard Clutch Maintenance 156 ...
Page 158: ...Structural Maintenance 158 ...
Page 168: ...Remote Evaporator Specifications 168 ...
Page 170: ...Remote Evaporator Maintenance Inspection Schedule 170 ...
Page 176: ...Remote Evaporator Electrical Maintenance 176 ...
Page 180: ...Remote Evaporator Refrigeration Service Operations 180 ...
Page 182: ...Remote Evaporator Structural Maintenance 182 ...
Page 184: ...Remote Evaporator System Diagnosis 184 ...
Page 188: ...Wiring and Schematic Diagrams Index 188 ...
Page 189: ...189 Wiring Diagram Page 1 of 4 ...
Page 190: ...190 Wiring Diagram Page 2 of 4 ...
Page 191: ...191 Wiring Diagram Page 3 of 4 ...
Page 192: ...192 Wiring Diagram Page 4 of 4 ...
Page 193: ...193 Schematic Diagram Page 1 of 3 ...
Page 194: ...194 Schematic Diagram Page 2 of 3 ...
Page 195: ...195 Schematic Diagram Page 3 of 3 ...
Page 196: ...196 ...