Unit Description
29
NOTE: The use of 50/50 percent pre-mixed ELC
is recommended to ensure that deionized water is
being used. If 100 percent full strength
concentrate is used, deionized or distilled water
is recommended instead of tap water to ensure
the integrity of the cooling system is maintained.
NOTE: Units equipped with ELC are not
necessarily equipped with EMI 2000, but units
equipped with EMI 2000 are equipped with ELC.
EMI 2000
EMI 2000 is an extended maintenance interval
package. It is standard equipment on this unit. The
EMI 2000 package consists of the following key
components:
•
New EMI 2000-Hour Cyclonic Air Cleaner
Assembly and Air Cleaner Element (standard
equipment on all TS Units)
•
New EMI 2000-Hour Fuel Filter (black with
gold lettering)
•
New EMI 2000-Hour By-Pass Oil Filter
(black with gold lettering)
•
API Rating CI-4 (ACEA Rating E3) Mineral
Oil
•
Five Year or 12,000 Hour ELC (Extended Life
Coolant)
The EMI package allows standard maintenance
intervals to be extended to 2,000 hours, or 1 year,
whichever occurs first.
NOTE: Units equipped with the EMI 2000
package do require regular inspection in
accordance with Thermo King's maintenance
recommendations.
SPECTRUM
™
Remote
Evaporator
A SPECTRUM
™
Remote Evaporator is located in
each compartment and can provide separate
temperature controlled areas.
Figure 4: SPECTRUM
™
Remote Evaporator
Compressor
The unit features a high performance 6 hp TKO
Scroll compressor.
SPECTRUM
™
TS HMI Control
Panel
The HMI (Human Machine Interface) Control
Panel consists of a display and eight touch
sensitive keys. The four keys on each side of the
display screen are used to turn the unit on and off,
initiate a manual defrost cycle, and select the high
speed lockout mode operation. The function of the
four keys located under the display screen
(referred to as “soft keys”) change as required by
the current menu shown on the display screen.
The display screen is used by the microprocessor
to provide visual prompt and display information
to the operator, such as operating mode, setpoints,
hourmeter readings and operating conditions of
the diesel engine. All information is shown in
English, with the ability to display in several other
languages.
Figure 5: HMI Control Panel
AJA1169
Summary of Contents for SPECTRUM TS 30 SR NAD
Page 4: ...4 ...
Page 10: ...Table of Contents 10 ...
Page 20: ...Safety Precautions 20 ...
Page 51: ...Unit Description 51 Figure 19 Front View Figure 20 Back View AJA1350 AJA1500 ...
Page 52: ...Unit Description 52 1 On Off Switch Figure 21 Side View 1 ...
Page 60: ...Unit Description 60 ...
Page 80: ...SPECTRUM TS Operation 80 ...
Page 90: ...Electrical Maintenance 90 ...
Page 100: ...Engine Maintenance 100 Figure 130 Early TK 3 95 Fuel and Oil System Components ...
Page 102: ...Engine Maintenance 102 Figure 131 Late TK 3 95 Fuel and Oil System Components ...
Page 104: ...Engine Maintenance 104 Figure 132 TK376 Fuel and Oil System Components ...
Page 136: ...Refrigeration Maintenance 136 ...
Page 156: ...Hilliard Clutch Maintenance 156 ...
Page 158: ...Structural Maintenance 158 ...
Page 168: ...Remote Evaporator Specifications 168 ...
Page 170: ...Remote Evaporator Maintenance Inspection Schedule 170 ...
Page 176: ...Remote Evaporator Electrical Maintenance 176 ...
Page 180: ...Remote Evaporator Refrigeration Service Operations 180 ...
Page 182: ...Remote Evaporator Structural Maintenance 182 ...
Page 184: ...Remote Evaporator System Diagnosis 184 ...
Page 188: ...Wiring and Schematic Diagrams Index 188 ...
Page 189: ...189 Wiring Diagram Page 1 of 4 ...
Page 190: ...190 Wiring Diagram Page 2 of 4 ...
Page 191: ...191 Wiring Diagram Page 3 of 4 ...
Page 192: ...192 Wiring Diagram Page 4 of 4 ...
Page 193: ...193 Schematic Diagram Page 1 of 3 ...
Page 194: ...194 Schematic Diagram Page 2 of 3 ...
Page 195: ...195 Schematic Diagram Page 3 of 3 ...
Page 196: ...196 ...