SPECTRUM™ TS Operation
64
Changing the Setpoint
At the Standard Display, press the soft key to
show the Zone Display for the desired zone. The
display below shows the Zone 2 display with a
setpoint of 35 F. The Zone is turned on as shown
previously.
Figure 51: Zone 2 Display
Pressing the “-” and/or “+” soft keys changes the
display to the Setpoint Display for the selected
zone. The display title changes and the YES and
NO soft keys appear as shown below. The “+” and
“-” soft keys are used to increase or decrease the
setpoint. Here the setpoint has been changed to 40
F using the “+” key.
NOTE: The allowable range for the setpoint is
limited if Setpoint Limits have been
programmed. Refer to the ThermoGuard
SPECTRUM TS Multi-Temp Microprocessor
Control System Diagnostic Manual (TK 51652)
for more information.
The YES and NO soft keys confirm the setpoint
change. When the desired setpoint has been
selected using the “+” and/or “-” keys, press the
YES soft key to confirm and load the new
setpoint. If the setpoint is changed using the “+”
or “-” keys, the change must confirmed or rejected
by pressing the YES or NO soft key within 10
seconds of changing the setpoint.
Failure to confirm the new setpoint by pressing
Yes or No within 10 seconds of changing the
setpoint will result in Alarm Code 127 (Setpoint
not entered).
Figure 53: Programming New Setpoint Display
After the YES soft key has been pressed the
display will briefly show PROGRAMMING
NEW SETPOINT as shown above.
The display then confirms the new setpoint for
several seconds as shown below.
Figure 54: New Setpoint
The display then returns to the Standard Display
showing the new setpoint.Notice that the Zone 2
arrow now points up to indicate the zone is
heating.
Figure 55: Standard Display With New Setpoint
Displayed
IMPORTANT: If the setpoint is changed using
the “+” or “-” keys, the change must be
confirmed or rejected by pressing the YES or NO
soft key within 10 seconds of changing the
setpoint.
•
If the YES key is pressed, the setpoint change
made with the “+” or “-”keys will be accepted,
the setpoint will be changed and the display
will return to the Standard Display.
1.
“-” Soft Key
2.
“+” Soft Key
3.
Yes Soft Key
4.
No Soft Key
Figure 52: New Setpoint Display
AJA1120
AJA1121
2
3
4
1
AJA1123
AJA1251
AJA1124
Summary of Contents for SPECTRUM TS 30 SR NAD
Page 4: ...4 ...
Page 10: ...Table of Contents 10 ...
Page 20: ...Safety Precautions 20 ...
Page 51: ...Unit Description 51 Figure 19 Front View Figure 20 Back View AJA1350 AJA1500 ...
Page 52: ...Unit Description 52 1 On Off Switch Figure 21 Side View 1 ...
Page 60: ...Unit Description 60 ...
Page 80: ...SPECTRUM TS Operation 80 ...
Page 90: ...Electrical Maintenance 90 ...
Page 100: ...Engine Maintenance 100 Figure 130 Early TK 3 95 Fuel and Oil System Components ...
Page 102: ...Engine Maintenance 102 Figure 131 Late TK 3 95 Fuel and Oil System Components ...
Page 104: ...Engine Maintenance 104 Figure 132 TK376 Fuel and Oil System Components ...
Page 136: ...Refrigeration Maintenance 136 ...
Page 156: ...Hilliard Clutch Maintenance 156 ...
Page 158: ...Structural Maintenance 158 ...
Page 168: ...Remote Evaporator Specifications 168 ...
Page 170: ...Remote Evaporator Maintenance Inspection Schedule 170 ...
Page 176: ...Remote Evaporator Electrical Maintenance 176 ...
Page 180: ...Remote Evaporator Refrigeration Service Operations 180 ...
Page 182: ...Remote Evaporator Structural Maintenance 182 ...
Page 184: ...Remote Evaporator System Diagnosis 184 ...
Page 188: ...Wiring and Schematic Diagrams Index 188 ...
Page 189: ...189 Wiring Diagram Page 1 of 4 ...
Page 190: ...190 Wiring Diagram Page 2 of 4 ...
Page 191: ...191 Wiring Diagram Page 3 of 4 ...
Page 192: ...192 Wiring Diagram Page 4 of 4 ...
Page 193: ...193 Schematic Diagram Page 1 of 3 ...
Page 194: ...194 Schematic Diagram Page 2 of 3 ...
Page 195: ...195 Schematic Diagram Page 3 of 3 ...
Page 196: ...196 ...