Electrical Diagnosis (Rev 6/98)
109
Fault in MV circuit
Test MV circuit
Faulty modulation valve coil
Test modulation valve coil
defective microprocessor
Replace microprocessor
Microprocessor Dead
Fuse open
Test fuse 12
Fault in 2P circuit
Test 2P circuit
Fault in CHP circuit
Test CHP circuit
Battery dead
Test battery
CONDITION
POSSIBLE CAUSE
REMEDY