7
Unit Description
The Super II SR+ uP IV+ is a one-piece, self-contained, die-
sel powered refrigeration-heating units. The unit mounts on
the front of the trailer with the evaporator portion extending
into the trailer. The unit uses hot gas to heat and defrost.
Power is provided by an se 2.2, a four-cylinder, water-
cooled, direct injection diesel engine rated at 27.8 continu-
ous horsepower (20.7 kilowatts) at 2200 rpm. An in-line
power pack provides direct drive power transfer from the
engine to the compressor. A belt drive system transfers
energy to the fans, the alternator, and the water pump.
The engine uses a spin-on, dual element, full flow/bypass
oil filter and “CD” rated petroleum engine oil for extended
1,500 hour maintenance intervals.
Additional unit features include the Thermo King X430
compressor and the THERMOGUARD uP IV+ Micropro-
cessor.
Thermo King X430 Compressor
The unit is equipped with a Thermo King X430, four-cylin-
der compressor with 492 cm
3
(30 cu. in.) displacement.
THERMOGUARD uP IV+ Microprocessor
The THERMOGUARD
uP IV+
is a microprocessor control
system designed for use with transport temperature control
systems. The
uP IV+
has the following features:
•
Thermostat
•
Digital Thermometer
•
Hourmeters
•
Oil Pressure Gauge
•
Water Temperature Gauge
•
Ammeter
•
Voltmeter
•
Tachometer
•
Mode Indicator
•
Refrigeration System Controller
•
Diagnostic System
The microprocessor mounts inside a weather tight control
box. The LCD display and alarm light are clearly visible
through a transparent door. Opening the control box door
provides quick access to the microprocessor keypad. The
keypad is used to control the operation of the microproces-
sor. See the Operation and Diagnosis Manual (TK 40893)
for details.
The CYCLE-SENTRY system and an integral defrost timer
are standard features. The refrigeration modulation system,
data recording, Tracker (a satellite communication system
interface) and remote indicator lights are optional features.
CYCLE-SENTRY Start-Stop Controls
A CYCLE-SENTRY Start-Stop fuel saving system provides
optimum operating economy. Select Continuous or
CYCLE-SENTRY operation using the selector switch
located on the switch panel.
WARNING: When the unit On-Off switch is in the
ON position, the unit may start at anytime without
prior warning.
NOTE: A buzzer sounds when the unit is automatically
preheating.
The CYCLE-SENTRY system automatically starts the unit
on microprocessor demand, and shuts down the unit when
all demands are satisfied. As well as maintaining the box
temperature, engine block temperature and battery charge
levels are monitored and maintained. If the block tempera-
ture falls below 30 F (-1.1 C), the engine will start and run
until the block temperature is above 90 F (32 C). If the bat-
tery voltage falls to the programmed limit selected by
CYCLE-SENTRY Battery Voltage (typically 12.2 volts)
and CYCLE-SENTRY mode is selected, the engine will
start and run until the battery is recharged.
Summary of Contents for Super II SR+
Page 4: ......
Page 10: ...ii ...
Page 14: ...4 ...
Page 22: ...Unit Description Rev 6 98 12 Front View AEA1350 ...
Page 23: ...Unit Description Rev 6 98 13 Right Side Door Open AEA1351 ...
Page 24: ...Unit Description Rev 6 98 14 Left Side Doors Open AEA1352 ...
Page 26: ...Operating Instructions Rev 6 98 16 Control Box Cover AEA1354 ...
Page 34: ...24 ...
Page 42: ...Electronic Controls Rev 6 98 32 SOFTWARE REVISION 04XX ALARMS AEA1358 ...
Page 82: ...72 ...
Page 90: ...80 ...
Page 116: ...106 ...
Page 120: ...110 ...
Page 130: ...120 ...
Page 141: ...131 Schematic Diagram SBIII SII RMNII 30 SR MPIV ...
Page 142: ...132 Wiring Diagram SII SBIII RMN30 SR MPIV Page 1 of 4 ...
Page 143: ...133 Wiring Diagram SII SBIII RMN30 SR MPIV Page 2 of 4 ...
Page 144: ...134 Wiring Diagram SII SBIII RMN30 SR MPIV Page 3 of 4 ...
Page 145: ...135 Wiring Diagram SII SBIII RMN30 SR MPIV page 4 of 4 ...