Electrical Maintenance (Rev 6/98)
44
•
A 15 amp fuse (F18—High Speed Solenoid) protects
the 7D circuit, which supplies power to the high speed
solenoid.
•
A 15 amp fuse (F21—#8F Circuit) protects the 8F cir-
cuit, which supplies power to various control relays and
components.
•
A number of three amp fuses protect microprocessor
circuits, control relay circuits, remote light circuits
(optional) and various components.
Relay Board
FUSE LINK
The fuse link is located on the left side of the engine near
the compressor. The fuse link protects the electric system
from a short in the 2 circuit. If the fuse link burns out, check
for a grounded 2 wire before replacing the fuse link.
aea803
Engine Low Oil Pressure Switch
Engine oil pressure should rise immediately on starting. The
switch will trip the reset switch and stop the engine if the oil
pressure drops below 103-138 kPa (15-20 psi). A continuity
tester is needed to check the oil pressure switch.
1.
Remove the 20A wire from the switch.
2.
The continuity tester should indicate a complete circuit
between each terminal and ground.
3.
Start the engine. The tester should show an open circuit
between each terminal and ground.
NOTE: The engine low oil pressure switch cannot be
repaired. It must be replaced.
THERMOGUARD µP IV+
MICROPROCESSOR CONTROLLER
Refer to the appropriate THERMOGUARD Microprocessor
Controller Operation & Diagnosis Manual for complete ser-
vice information about the Microprocessor Controller and
the related components.
DEFROST SYSTEM
The unit should be run through a defrost cycle during unit
pre-load operation and every 1000 operating hours to test
defrost system components. To check the defrost cycle, run
the unit on COOL and adjust the microprocessor setpoint to
drop the evaporator coil temperature below 7.2° C (45° F).
Press the manual defrost switch. The unit should shift from
COOL to the defrost cycle.
If the unit continues on cooling, double check the evapora-
tor coil temperature and refer to the “Defrost Check Out
Procedure,” in this chapter.
NOTE: When the unit is in DEFROST, it will operate on
low speed.
Summary of Contents for Super II SR+
Page 4: ......
Page 10: ...ii ...
Page 14: ...4 ...
Page 22: ...Unit Description Rev 6 98 12 Front View AEA1350 ...
Page 23: ...Unit Description Rev 6 98 13 Right Side Door Open AEA1351 ...
Page 24: ...Unit Description Rev 6 98 14 Left Side Doors Open AEA1352 ...
Page 26: ...Operating Instructions Rev 6 98 16 Control Box Cover AEA1354 ...
Page 34: ...24 ...
Page 42: ...Electronic Controls Rev 6 98 32 SOFTWARE REVISION 04XX ALARMS AEA1358 ...
Page 82: ...72 ...
Page 90: ...80 ...
Page 116: ...106 ...
Page 120: ...110 ...
Page 130: ...120 ...
Page 141: ...131 Schematic Diagram SBIII SII RMNII 30 SR MPIV ...
Page 142: ...132 Wiring Diagram SII SBIII RMN30 SR MPIV Page 1 of 4 ...
Page 143: ...133 Wiring Diagram SII SBIII RMN30 SR MPIV Page 2 of 4 ...
Page 144: ...134 Wiring Diagram SII SBIII RMN30 SR MPIV Page 3 of 4 ...
Page 145: ...135 Wiring Diagram SII SBIII RMN30 SR MPIV page 4 of 4 ...