All installations and services must be performed by qualified service personnel.
52
TROUBLESHOOTING GUIDE
THE SYSTEM IS STARTED BY SETTING THE THERMOSTAT TO CALL FOR
HEAT. THE FOLLOWING SHOULD HELP ESTABLISH THE TYPE OF
MALFUNCTION OR DEVIATION FROM THE NORMAL OPERATION.
TO USE THIS DIAGRAM, YOU JUST NEED TO FOLLOW THE INSTRUCTIONS IN THE BOXES.
TURN THERMOSTAT TO CALL FOR HEAT
DOES THERMOSTAT MAKE
IS ROOM TEMPERATURE
BELOW
SETTING?
IS ROOM
TEMPERATUR
ABOVE 90 DEGREES F?
TURN T'STAT
SETTING
ROOM TEMP.
COOL THE THERMOSTAT
IS THE TRANSFORMER
SUPPLYING 24 VOLTS
TO THE THERMOSTAT?
REPLACE
THERMOSTAT
IS INTERNAL DAMAGE
PRESENT ON
TRANSFORMER
CHECK INPUT
POWER,
INTERLOCK,
SERVICE SWITCH
AND FUSES.
No
CHECK
CONTINUITY
& PROPER
CONNECTIONS
REPLACE 24V
TRANSFORMER
No
Yes
Yes
REPLACE TRANSFORMER
No
Yes
Yes
No
No
Yes
ARE WIRES CONNECTED
PROPERLY?
No
CORRECT WIRE
CONNECTIONS
No
Yes
Yes
No
Yes
IS THE INDUCER
BLOWER OPERATING?
Yes
IS THERE 24 VOLTS
ACROSS "R" & "C"
AT THE INTEGRATED
CONTROL
Summary of Contents for CLQS1-050T36N
Page 2: ......
Page 4: ......
Page 47: ...All installations and services must be performed by qualified service personnel 45...
Page 55: ...All installations and services must be performed by qualified service personnel 53...
Page 56: ...All installations and services must be performed by qualified service personnel 54...
Page 57: ...All installations and services must be performed by qualified service personnel 55...
Page 59: ...All installations and services must be performed by qualified service personnel 57...
Page 60: ...All installations and services must be performed by qualified service personnel 58...