10
B. VENTING:
NOTE:
On the THV1M119A* it is possible to rotate the flue elbow (which is factory installed for vertical
discharge) 90° counter clockwise or clockwise from the vertical position to adapt to various venting
systems.
Notice
: Blocked Vent Switch Installation
The blocked vent switch kit must be installed to comply with CAN STD B140.4 where applicable. For
installation instructions see RAOPS2687 kit.
CAUTION MUST BE TAKEN NOT TO EXCEED 90°
ROTATION (OF THE FLUE
ELBOW) .
ROTATION OF FRONT FLUE ELBOW:
When an installation requires that the flue exit out the left or right side casing, remove the screw securing
the 90 deg. elbow and rotate it 90°. Then, remove knock-out in side casing and extend vent through the
opening.
A trim collar may be ordered to hide the gap around the flue pipe. This trim collar, however, is not
required for operation. Trim collar/gasket part numbers(s) R14132 / R330006 for THV1M119A*.
The THV1M119A* may be vented through a standard correctly sized chimney.
The THV1M119A* may also be horizontally vented through a sidewall. A field model FDVS-67/FOVP-615
side wall vent kits for such applications is available. When installing the sidewall vent kits, outside
combustion air must also be applied to the burner. The following table identifies application order
information.
Table 2: Sidewall vent kits
The Field vent kit is set up with a 6 inch diameter vent pipe for the THV1M119A* with concentric through-
the-wall vent termination/inlet air vent hood. For Beckett, the combustion air inlet pipe will be reduced to
3” diameter with the Beckett sidewall vent kit.
The side wall vent may be installed either through the knock-out on the right or left side casing of the unit
or vertically out the top opening of the vestibule.
The combustion air inlet can be installed through the either the lower left side casing knockout or the
lower right side casing knockout.
FIELD VENT TERMINATION
KIT
SIDE WALL VENT
ACCESSORIES KIT
COMBUSTION AIR INTAKE
HOOD KIT
(15’ application MAX)
(BURNER SPECIFIC)
(FOR COMBUSTION AIR
APPLICATIONS ONLY)
PART NUMBER
PART NUMBER
PART NUMBER
THV1M119A*
Beckett AFG
RAOPS8414
RAOPS8394
RAOPS8397
BURNER
SIDE WALL VENTING APPLICATION ORDER INFORMATION
Summary of Contents for THV1M119A960SA
Page 2: ......
Page 4: ......
Page 6: ...2...
Page 36: ...32 V Sequence of Operations Flow Chart...
Page 37: ...33...
Page 38: ...34 VI Trouble Shooting Flow Chart...
Page 39: ...35...
Page 40: ...36...
Page 41: ...37...
Page 42: ...38...
Page 44: ...40 Appendix A Replacement Parts for THV1M119A...
Page 45: ...41...
Page 46: ...42 Appendix B THV1M119A960SA PSC Wiring Diagram...