Basic Operation 

Testing Services 

Thermo Scientific 

AerosolSense Manual     

2-7

 

 

The sample is ready to be sent to a lab for testing. See the following next 

steps depending on whether you are using an on-site lab, a third-party lab, 

or the Thermo Fisher Scientific testing services. 

The sample is now ready to be processed using the steps in the 

AerosolSense sample preparation procedure. To download the procedure, 

visit the In-Air Pathogen Surveillance Solution support page at: 

www.thermofisher.com/apssupport

 

The sample is now ready to be sent to your choice of a third-party testing 

lab. Please advise your testing lab to follow the AerosolSense sample 

preparation procedure in order to support testing protocol. To download 

the procedure, visit the In-Air Pathogen Surveillance Solution support page 

at: 

www.thermofisher.com/apssupport

 

The following steps apply if the sample is being mailed to an external 

partner laboratory as part of the testing service. The shipping material is 

included. 

1.

 

Assemble the box. 

2.

 

Place the sealed biohazard safety bag that contains the sample cartridge 

into the box and seal the box. 

3.

 

Adhere the shipping label to the box and send it out for shipping. 

 

Figure 2–12.

 Required Packaging for Shipping 

Testing Services 

Self-Testing On-site 

Lab 

Third-Party Testing 

Lab 

Thermo Fisher 

Scientific Testing 

Services 

Summary of Contents for AerosolSense 2900

Page 1: ...AerosolSense 2900 Sampler Manual In air pathogen surveillance solution Part Number 121561 00 18March2021...

Page 2: ......

Page 3: ...tridge 2 2 Removing the Sample Cartridge 2 5 Testing Services 2 7 Self Testing On site Lab 2 7 Third Party Testing Lab 2 7 Thermo Fisher Scientific Testing Services 2 7 Cleaning Instructions 2 8 Safet...

Page 4: ......

Page 5: ...ty safety protocols Confidently help protect employees and communities while maintaining business and operational continuity Figure 1 1 AerosolSense 2900 Sampler The AerosolSense Sampler has the follo...

Page 6: ...e cartridge is removed placed into a biohazard bag and sent to a laboratory for PCR testing There are three laboratory testing options 1 self testing at on site lab 2 third party lab testing or 3 Ther...

Page 7: ...Introduction Product Description Thermo Scientific AerosolSense Manual 1 3 Figure 1 3 AerosolSense Sampler Front View Figure 1 4 AerosolSense Sampler Inside View...

Page 8: ...Introduction Product Description 1 4 AerosolSense Manual Thermo Scientific Figure 1 5 AerosolSense Sampler Back View...

Page 9: ...le collection holder and media Single use sampling cartridge containing 2 1 inch collection substrates Safety and electrical designations TUV SUD CE UKCA ROHS Sample flow control 200 L per minute Oper...

Page 10: ......

Page 11: ...bstructed 2 Plug the power cord into an outlet with the appropriate voltage Equipment Damage The AerosolSense Sampler is supplied with a three wire grounding cord Under no circumstances should this gr...

Page 12: ...mple cartridge in the sampler 1 Open the front door of the sampler using the key 2 Unscrew the sample cartridge cap and screw it onto the tray for storage Figure 2 2 Unscrewing the Sample Cartridge Ca...

Page 13: ...clockwise to screw it on until it no longer turns 5 Make sure that the collection substrate is facing up Figure 2 4 Collection Substrate Facing Up 6 Fully push in the plunger The LED will flash green...

Page 14: ...AerosolSense Manual Thermo Scientific 7 Close the door and lock using the key The LED will be solid yellow to show the system is ready to sample Figure 2 6 Closing the Door 8 The LED will turn green...

Page 15: ...time has elapsed proceed to remove the sample cartridge The LED will remain green until the sampler door is opened When the door is opened the LED will turn red Note The key is needed to open the doo...

Page 16: ...4 Turn the cartridge counter clockwise until it comes out of the sample cartridge port Figure 2 10 Turning the Sample Cartridge Counter Clockwise 5 Screw on the cartridge cap Figure 2 11 Sample Cartri...

Page 17: ...arty testing lab Please advise your testing lab to follow the AerosolSense sample preparation procedure in order to support testing protocol To download the procedure visit the In Air Pathogen Surveil...

Page 18: ...Basic Operation Cleaning Instructions 2 8 AerosolSense Manual Thermo Scientific Perform periodic cleaning with an alcohol based wipe as appropriate based on the sampler usage Cleaning Instructions...

Page 19: ...ill result in death or serious personal injury if the warning is ignored A hazard is present or an unsafe practice can result in serious personal injury if the warning is ignored The hazard or unsafe...

Page 20: ...s may be new or refurbished at the election of Seller All replaced parts shall become the property of Seller Shipment to Buyer of repaired or replacement Products shall be made in accordance with the...

Page 21: ...PRIOR WRITTEN APPROVAL OR ANY USE OF REPLACEMENT PARTS NOT SUPPLIED BY SELLER SHALL IMMEDIATELY VOID AND CANCEL ALL WARRANTIES WITH RESPECT TO THE AFFECTED PRODUCTS THE OBLIGATIONS CREATED BY THIS WAR...

Page 22: ...mo Fisher Scientific s compliance with these Directives the recyclers in your country and information on Thermo Fisher Scientific products which may assist the detection of substances subject to the R...

Page 23: ...1 Figure 2 2 Unscrewing the Sample Cartridge Cap 2 2 Figure 2 3 Aligning the Cartridge 2 2 Figure 2 4 Collection Substrate Facing Up 2 3 Figure 2 5 Plunger In 2 3 Figure 2 6 Closing the Door 2 4 Figu...

Page 24: ......

Page 25: ......

Page 26: ...ermofisher com aerosolsense 2021 Thermo Fisher Scientific Inc All rights reserved All trademarks are the property of Thermo Fisher Scientific and its subsidiaries unless otherwise specified EPM_Aeroso...

Reviews:

Related manuals for AerosolSense 2900