background image

Thermo Scientific Jewett CTF306 Blood Plasma Freezers

Installation and Operation

WEEE Compliance

WEEE Compliance

. This product is required to comply with the European 

Union’s Waste Electrical & Electronic Equipment (WEEE) Directive 2002/96EC. 
It is marked with the following symbol. Thermo Fisher Scientific has contracted 
with one or more recycling/disposal companies in each EU Member State, and this 
product should be disposed of or recycled through them. Further information on 
our compliance with these Directives, the recyclers in your country, and 
information on Thermo Scientific products which may assist the detection of 
substances subject to the RoHS Directive are available at 

www.thermo.com/

WEEE Konformittät

. Dieses Produkt muss die EU Waste Electrical & Electronic 

Equipment (WEEE) Richtlinie 2002/96EC erfüllen. Das Produkt ist durch 
folgendes Symbol gekennzeichnet. Thermo Fisher Scientific hat Vereinbarungen 
getroffen mit Verwertungs-/Entsorgungsanlagen in allen EU-Mitgliederstaaten 
und dieses Produkt muss durch diese Firmen widerverwetet oder entsorgt werden. 
Mehr Informationen über die Einhaltung dieser Anweisungen durch Thermo 
Scientific, dieVerwerter und Hinweise die Ihnen nützlich sein können, die Thermo 
Fisher Scientific Produkte zu identizfizieren, die unter diese RoHS. 
Anweisungfallen, finden Sie unter 

www.thermo.com/

Conformità WEEE. 

Questo prodotto deve rispondere alla direttiva dell’ Unione 

Europea 2002/96EC in merito ai Rifiuti degli Apparecchi Elettrici ed Elettronici 
(WEEE). È marcato col seguente simbolo.Thermo Fischer Scientific ha stipulato 
contratti con una o diverse società di riciclaggio/smaltimento in ognuno degli Stati 
Membri Europei. Questo prodotto verrà smaltito o riciclato tramite queste 
medesime. Ulteriori informazioni sulla conformità di Thermo Fisher Scientific con 
queste Direttive, l’elenco delle ditte di riciclaggio nel Vostro paese e informazioni 
sui prodotti Thermo Scientific che possono essere utili alla rilevazione di sostanze 
soggette alla Direttiva RoHS sono disponibili sul sito 

www.thermo.com

/

Conformité WEEE. Ce produit doit être conforme à la directive euro-péenne 

(2002/96EC) des Déchets d’Equipements Electriques et Electroniques (DEEE). Il 
est marqué par le symbole suivant. Thermo Fisher Scientific s’est associé avec une 
ou plusieurs compagnies de recyclage dans chaque état membre de l’union 
européenne et ce produit devraitêtre collecté ou recyclé par celles-ci. Davantage 
d’informations sur laconformité de Thermo Fisher Scientific à ces directives, les 
recycleurs dans votre pays et les informations sur les produits Thermo Fisher 
Scientific qui peuvent aider le détection des substances sujettes à la directive 
RoHS sont disponibles sur www.thermo.com/

Great Britain

Deutschland

Italia

France

 
13

Summary of Contents for Jewett CTF306

Page 1: ...Installation and Operation Manual Thermo Scientific Jewett CTF306 Blood Plasma Freezers...

Page 2: ...2009 Thermo Fisher Scientific All rights reserved Suva is a registered trademark of DuPont All other trademarks are the property of Thermo Fisher Scientific Inc and its subsidiaries...

Page 3: ...peration Do not adjust the refrigerant valves or the temperature control 7 Use of electrical characteristics other than those specified on the serial plate will cause permanent damage to the mechanism...

Page 4: ...2...

Page 5: ...3...

Page 6: ...ormed according to the temperature measured by the thermostat probe with a positive differential from the set point if the temperature increases and reaches set point plus differential the compressor...

Page 7: ...2 100 P2 CCt Compressor ON time during continuous cycle 0 0 24 0h res 10min Allows to set the length of the continuous cycle compressor stays on without interruption for the CCt time Can be used for i...

Page 8: ...The alarm stops just after the digital input is de activated 8 3 SERIOUS ALARM MODE i1F bAL When the digital input is activated the unit will wait for did delay before signalling the CA alarm message...

Page 9: ...P Third probe presence n not present Y pres n Pr2 O3 Third probe calibration 12 12 C 120 120 F 0 0 0 Pr2 P4P Fourth probe presence n not present Y pres n Pr2 O4 Fourth probe calibration 12 12 C 120 12...

Page 10: ...ce to removal of the dollar bill test strip should be felt Check the perimeter of the door If the latch is loose see latch adjusting information 5 Replace cover plate A Note To accomplish different of...

Page 11: ...line solenoid will not open 10 Repair or replace coil 1 Low voltage to unit 1 Determine reason and correct 2 Start capacitor failure or wrong 2 Replace start capacitor 3 Run capacitor failure or wrong...

Page 12: ...nt 1 Leak check and repair 2 Control contacts stuck or frozen 2 Clean contacts or replace control 3 Refrigerated air space has an excessive load 3 Determine reason and correct 4 Dirty Condenser 4 Clea...

Page 13: ...lve 1 Defrost duration too long 1 Adjust defrost termination 2 Fan delay not delaying fans after defrost period 2 Defective fan delay thermostat Replace 3 Defective timer 3 Replace N Ice accumulating...

Page 14: ...unter diese RoHS Anweisungfallen finden Sie unter www thermo com Conformit WEEE Questo prodotto deve rispondere alla direttiva dell Unione Europea 2002 96EC in merito ai Rifiuti degli Apparecchi Elet...

Page 15: ...e information can be found on the dataplate attached to the equipment If available please provide the date purchased the source of purchase manufacturer or specific agent rep organization and purchase...

Page 16: ...Thermo Fisher Scientific Inc 275 Aiken Road Asheville NC 28804 United States www thermofisher com 306650H01 Rev D...

Reviews: