Ramsey Oretronic IV Tramp Metal Detector REC 4479C
Page 42
Figure 3
–
6. View menu with Password entry field visible.
Normal Operation
The screen that you will see upon power-
up is the Home (or “Run”) screen. This screen shows the total count
of detected tramp (or total trips) since the last factory reset or software update operation. When metal is
detected, an additional field is displayed with the label “Coast” which is the number of pieces of tramp
detected since the TMD IV
tripped (or while the belt was “coasting” to a stop). Pressing the RESET
(bell) key or
the external Reset button sets the coast counter to zero.
From the home screen, a number of additional screens can be entered, using the “soft keys” along the bottom
of the screen. These screens allow the user to change system options, change settings, calibrate the TMD IV,
and perform various service operations. In order to select an option, use the up-and-down soft keys to
highlight the option, then press the “Select” or “Edit” soft key (if neither
soft key is displayed, then the
selected value is read-only).
The Select soft key indicates that a limited set of values is defined, the up-and-down soft keys will be used to
change the value displayed. The Edit soft key indicates that a value must be entered from the numeric keypad.
For Edit fields, an “Accept” key will not be visible if the entered value is outside allowed range.
It’s important to note that no change is actually set until the Accept key is pressed. If the Cancel key is
pressed, the display will go back into item selection mode, with the previous value unchanged. HOME keypad
key is pressed while in Edit or Select mode, the previous value is unchanged.