28
3.0
Installation alternative 6
– Corner refrigerator with air vent/air
barrier
10. Ensure that the hole in the modular wall is 440x480 mm Distance from the ceiling to the top of
the light aperture minimum 80 mm. Minimum air flow between grates 200 cm²
11. Install the plug 2200mm from the floor and up, and 800mm from the corner and out.
12. NB! Must be conducted by an authorised electrician.
13. If an air conduit going from the floor to the ceiling has not been installed to the rear wall, an air
barrier must be installed. See figure
14. You must install/there must be installed 1 ventilation grate at the base and 2 ventilation grates
over the door in a kitchen with a high ceiling.
15. Lift the cooling unit into the cooling corner. Let it rest on the floor or a shelf. The mains cable is
pushed up and out over the air duct and is fastened so that it cannot slip down into the air duct
again. Do not connect the plug to a socket
16. Push the cooling unit in and fix it with screws in each corner. The gasket should seal against
the wall.
17. Connection to existing lighting:
1. Loosen the set screw
2. Squeeze the locking hook together and lift the lid
3. The cables are connected to N and L.
4. Fasten the cable under the strain reliever
5. Squeeze the lid back in place and screw in the set screw.
The connection for illumination is at the top of the cooling unit. The outlet provides 12V LED
When connecting a spotlight with a G4 bulb type: The light source must be switched to the
bulb type: LED 12V G4 0.9W
When connecting an LED rail along the door No measures necessary
18. Connect the plug to the outlet and make sure the unit starts up.