PT59X

Room thermostat with the option to regulate domestic hot
water (DHW) and remote control by mobile telephone for
boilers with OpenTherm communication

- opening the main menu
-

ESC(escape)

=return one step back 

- browse through the main menu (view)
- browse in the “

Parameters

” mode

- in the “

Setting program

” browse between time intervals

- browse (view) information by pressing ”    “

-

ENTER= acknowledgement

= typing changes

- quick change of the requested temp.

(short-term in the mode  “

Auto

”, 

permanent in the “

Manual

” mode)

- change in the adjusted value 

- Press the button “LCD” to select the appearance of the introductory display of information on the display

01.01.13

21:45

Thuesday

AUTO

prog:1

per.:1

IN:19.0°C        DHW:50.0°C      OT+

22.4

°

C

Temp. DHW: 57°C

OT+

Temp. DHW: 57°C

OT+

actual

IN:

22.4°C

UT:

42.0°C

OUT:

8.0°C

required

IN:

19.0°C

CH:

0.0°C

DHW:

50.0°C

Actual temp.

: 22.5°C

required IN

: 19.0°C

required DHW

: 50.0°C

outdoor:

8.0°C

- press “     “ for view following information      ---------->>>>> by  

TURNING

“        “ button next information

(about the heating system, the supply of hot service water, servicing, the outside temperature etc.) 

- serves for fast copy of days in the “ Setting program” mode
- entrance/leaving into/from the service mode, press the button during about 5 s in the introductory display.

- Press the button to open the browse menu and the change the actual requested room temperature and the
automatic or manual mode
Turn the button “        “ to change the actual value of the requested temperature (in automatic mode up to the
further time section) or select another programme. 
Turn the button “

“ to switch between the temperature and the programme

LCD

COPY

1

2

3

4

5

6

7

Control elements

Button function

- PRESSING

Button function

- TURNING

1

2

3

4

5

6

7

01.01.13

21:45

Thuesday

AUTO

prog:1

per.:1

01.01.13

21:45

Thuesday

AUTO

prog:1

per.:1

Required CH

= calculated 

central heating

according 

to he selected equitherm curve, according to the
weather) irrespective of min. and max, potential temper-
ature of CH, the data in brackets is the requested temp.
with respect to the adjusted min. and max. CH temper-
ature (see pages 6, 7 – constants No. 6 and 7)

Actual CH 

= actual temperature of heating water

Modulation 

= modulation output of the boiler in %

Flow

= information about the flow of DHW in litres per

minute for boiler 

СХ

and 

ТСХ

Required  temp. DHW

= required DHW temperature

Operating hours CH and DHW

= reset by ”

LCD

”button

Temp. measured

= statistics value, reset by ”

LCD

”button

Works boiler inspector

= service telephone (see page 5)

Required temp. in AUTO/MANU mode

= change by

“     “, short-term in “Auto”, permanent in “Manual” mode

Outdoor temp.

= temperature on the outside temperature

sensor connected to the boiler

Required temp. in premature switching mode

constant No. 3

- Display backlight (after pressing any button the display is automatically backlit for about 2 s.)

LCD

COPY

DESCRIPTION

UT

sign for heating on

1

On the last line is further information, for example, the outside temperature 

A)

B)

C)

Summary of Contents for PT59X

Page 1: ...nual mode Turn the button to change the actual value of the requested temperature in automatic mode up to the further time section or select another programme Turn the button to switch between the temperature and the programme LCD COPY 1 2 3 4 5 6 7 Control elements Button function PRESSING Button function TURNING 1 2 3 4 5 6 7 01 01 13 21 45 Thuesday AUTO prog 1 per 1 01 01 13 21 45 Thuesday AUTO...

Page 2: ...equested temp is performed by pressing the or button cannot be set when in the OFF mode or the Summer mode Press the button by turning select the Manual mode confirm by button The quick change of the requested temperature is performed similarly as when in automatic mode Press the button by turning select the Auto off mode confirm by button Mode OFF in automatic is cancelled by selection of another...

Page 3: ... of the mode in which the thermostat will work 0 Required temper regulation the thermo stat heats for requested temp at the stated time 1 Premature switching PS during two day of opera tion the thermostat ascertains thermal constants of the reference room and then switches the heating with requested advance for restriction of advance see constant No 5 below 2 Summer mode the thermostat does not he...

Page 4: ... and press the button to confirmation In the case of selection of equithermal regulation follow the instructions under the graph with the heating curves If selecting a requested room temperature of other than 20 C the thermostat calculates the automatic shift of the curve according to the following equation where the coefficient is 1 shift requested temper 20 coefficient Note the most frequently u...

Page 5: ... regulation and follow instructions shown at the graph Turn the button to consequently set day month and year for the revision and confirm each setting by the To speed up the setting press the button COPY which displays the actual date The revision is cancelled by the change of the date of revision After setting constant No 17 automati cally appears or 15 in service mode At the stated date the tex...

Page 6: ...entered ust be acknowledged by the button After setting the last number constant No 20 automatically appears 1st numeral The telephone number is entered in the international format without or 00 at the beginning In the case that the telephone number has 10 or 11 digits an empty place is set on the last position after entering the last number Press the button to switch to the next constant In the c...

Page 7: ... where x are values within the range 0 to 5 0 cannot be determined or no signal is detected 1 the worst signal level 5 the best signal level FORMAT FOR BACK MESSAGES FROM PТ59X Off Deactivated heating system Off AUTO The thermostat is in automatic mode MANU The thermostat is in manual mode Noakcept Signals an error incorrectly entered SMS etc xx x temperature in C Note In the case of exceeding the...

Page 8: ...se of not keeping to the intended manner of use and maintenance of the product 4 intervention by unauthorized persons into the product 5 unprofessional repair of the product The OpenTherm protocol enables to send important error messages from the boiler into the thermostat The thermostat displays these messages on the last line of the display E xxx where xxx can be from 001 to 255 This type of err...

Reviews: