25. Version
(reset of the factory setting)
Only for information regarding the firmware version of
the thermostat. Option to reset the factory setting
-
reset
.
Setting
Constants
Pr
ogr
amming and
setting par
amet
e
rs
Main menu
6
17. Temper. 2nd sensor
(factory setting “not used”)
Option to use the external room sensor (not the outdoor
temperature sensor).
Disconnect =
external sensor is not connected, if connected,
it functions as an indoor sensor and regulation is according to
the temperature measured on the connected sensor.
For DHW =
external sensor is placed in water tank and
regulate DHW (temper.program select for DHW see
page3).
15.0°C to 80.0°C =
external sensor is used to restrict the
maximum temperature (e.g. heated floor, etc).
18. Use GSM
(factory setting NO)
Option to use GST1 module for remote control of the
thermostat by mobile telephone.
NO =
modul GST1 module is not connected
YES =
modul GST1 is connected, the following
constants No. 20 and 21 must be set and the module
must be connected according to the respective manual!
19. Phone No. 1
Entering the telephone number in an international
format (79876543210),
to which SMS are sent
back regarding the status of the thermostat
.
79876543210
22. Pin
Setting the PIN code for the SIM card which is
inserted into the GST1 module.
* * * *
The version number of the firmware appears with the text
“
COPY
“. With the second pressing of the button „
COPY
“ (for
about 5 s) there is RESET OF THE FACTORY SETTING (on
the display above this button the text is displayed “reset“). To
return to the main menu use the “ “ button.
If the sensor is connected, the text will appear at the constant “
Sensor connected
”. In the introductory LCD the value of
the temperature of the external sensor appears “
External sensor: XX.X°C
.
If the sensor is not connected (or the sensor was disconnected) and constant No. 17 is set for the use of this sensor, the
notification “
External sensor error
” appears. In information, a new item appears according to the use of the external sensor:
“
Regulation according to the 2nd sensor
“
/
“
Temp.DHW sensor
“
/
“
Temp. 2nd sensor
“.
Turn the “ “ in upward direction and set maximum temper-
ature measured by the external sensor (within the range 15 °C
to 80 °C), at which there is the disconnection of the boiler.
Setting is confirmed by pressing the “ “.
If the temperature measured by the external sensor reaches
the set value, there is the disconnection of UT and
on the display, the text “
Disconnected-external sensor
appears
“.
After setting, constant No. 18 appears.
Turn the “ “ button to set the option for using the module
GST1and press the button “ ” to confirm. There is the
automatic appearance constant No. 19 (if the module is not
used, constants 19, 20, 21, 22 is automatically skipped).
Turn the button “ “ to gradually set the numbers which
correspond to the telephone number for sending SMS
messages sent from the thermostat. Each number entered
ust be acknowledged by the button “ “. After setting the
last number, constant No.20 automatically appears
1st numeral
The telephone number is entered in the international format
(without “+“ or “00“ at the beginning). In the case that the
telephone number has 10 or 11 digits, an empty place is set on
the last position after entering the last number. Press the button
“ “ to switch to the next constant. In the case that you do not
want to enter the next telephone number, constant No. 20
“Phone No. 2” and No.21 “Phone No. 3” are left empty. When
setting constants No. 20, 21 the procedure is the same!
1st numeral
Individual characters of the PIN are not visible due to the
high level of security against misuse of the SIM card.
Turn the “ “ button to gradually enter the PIN code for the
card, to be inserted into the GST1 module. Each time the
number is entered it must be confirmed by “ “. After enter-
ing the last number PIN code, connect the conductor into the
GST1 module and connect the module into the socket. As
soon as the orange diode lights up, press the button “
COPY
”
(on the display above this button the following text is displayed
“
1st attempt of 3
”). Then, there is the testing of the correct
connection of module GST1 and verification of the PIN code.
If the PIN is incorrectly entered, the following text appears “In-
correct PIN“ and “
2nd attempt of 3
”. In the case of further
incorrect entering of the PIN, the following text appears “ Last
attempt”.
.
23. Legionella function
(factory setting NO)
Ensures the control of the TUV tank for the minimum
temperature of 60°C, which kills all potential Legionella
bacteria.
NO = the function is not active
YES =
the function is active, the value in the bracket is the
number of days, which remain to the automatic heating
(always
by 5 days, if the temperature of the TUV does not exceed 60°C)
Turn the “ “ button to set the option and press the ” “
button to confirm. Constant No. 25 automatically appears.
Conditions for the correct function:
There must be information about the temperature of the DHW
from the boiler or the 2nd sensor must be in the function for
„HSW“!
The automatic heating always takes place at midnight.
20. Phone No. 2
Entering the telephone number in the international
format (79988776543) - not obligatory.
21. Phone No. 3
Entering the telephone number in the international
format (79988776543) - not obligatory.
When setting telephone numbers 2 and 3, the function is as follows:
1, SMS “ Info” will be sent from tel. numbers 2nd or 3rd, answer will be
sent to tel. number 2nd or 3rd;
2, SMS “Temp xx” will be sent from tel. numbers 2nd or 3rd, answer will
be sent to tel. number 1st;
3, If an error status is reported, an SMS is sent to tel. no. 1, 2 and 3;
4, If an SMS is sent from other tel. number, the reply is always sent only
to tel. number 1st.
5, SMS “Call” will be sent, the call is only on tel. number 1
!
If the PIN is incorrectly entered three times, disconnect the module
and restart the thermostat. Remove the SIM card and insert it into the
telephone and activate the SIM card by entering the PIN. Then enter
the PIN again!