Page 6
2. Installation
2.1
Transport instructions
The machine comes to you
in a box or shrink wrap. If you have to
transport the machine at any time it is recommended that you use a similar
box and packing methods. Please let the machine cool down and lower the
handle to the locked position.
2.2
Installing the machine
2.2.1
Remove all
packaging from the heat press.
2.2.1
Check to ensure
that no damage has been caused to the machine
during transit.
2.2.3
Place the machine
on a sturdy horizontal surface that is within
easy reach of the operator and allow space for the handle to move
up to the loading position. Ensure that no items vulnerable to heat
radiation are too close to the machine and that local lighting is
adequate.
2.3
Electrical requirements
The NL-22 press should
be connected to the mains supply, (nominally
230V AC for the European Market, or 120V AC for America) by the mains
cable provided and a suitable plug. A qualified person should carry out this
work.
The press is designed
for 220-230 volts AC
±
50/60 hertz and requires
exclusive use of a power outlet rated for at least 5 amps (Europe),
or for 120 volts AC
8 amps (America).
Ensure that
the supply rating on the machine specification plate
corresponds with your local supply and that the correct plug is fitted.
MAINS LEAD
The wires
in this mains lead are coloured in accordance with the following
code:
Green and Yellow
:
EARTH
(GREEN)
230 VAC Blue
:
NEUTRAL
(WHITE)
120 VAC
Brown:
LIVE
(BLACK)
As the colours
of the wires in the mains lead of this apparatus may not
correspond with the coloured markings identifying the terminals in your
plug, proceed as follows: -