Page
12
Manuale d'installazione, uso e manutenzione
SOFIA
– ILARIA – VITTORIA – ANNA
B
– Smoke by-pass
This device creates a direct bypass for the flue gases which facilitates both the lighting and refuelling operations. The rid dling tool
provided must be used when activating it and only when lighting or stoking the fire.
IT IS PROHIBITED TO LEAVE THE SMOKE BY-PASS OPEN DURING NORMAL OPERATION.
Leaving the Smoke by-pass open during normal operation results in higher fuel consumption than the declared
quantity, a considerable drop in efficiency and exposure of the appliance to extremely high temperatures. For this
reason the warranty does not cover any direct or indirect damages caused by prolonged exposure of the appliance to
these temperatures.
ATTENTION: The temperature of the Smoke by-pass is very hot while the appliance is
operating, so take care not to touch it. The riddling tool provided must be used when handling it.
Pulling the lever outwards activates the smoke bypass, whereas pushing it inwards activates the normal flue gas path.
F
– Primary air control
It is used to regulate the primary air inflow. The primary air passes through
the grate of the firebox and fuels the combustion to determine its power
and speed. Rotate the control counterclockwise to reduce the air inflow.
On the contrary, rotate the control clockwise to increase the air inflow.
ATTENTION: When the appliance is operating the
temperature of the primary air control is very high, so
take care not to touch it. The glove provided must be
worn when handling it.
G
– Combustion secondary air levers
Controls the secondary air inflow which preheats as it passes through the
holes in the back of the combustion chamber and facilitates triggering the
second combustion. Shift one of the two levers to the left to reduce the air
inflow. Whereas to increase the inflow air shift it to the right.
ATTENTION: The temperature of the secondary air
levers is very hot while the appliance is operating, so
take care not to touch them. The glove provided must
be worn when handling them.
Smoke by-pass