Installation, use and maintenance guide
ARDHEA EVO5
– ARDHEA-F EVO5
Page
11
ENG
4
–
INSTALLATION
4.1 APPLIANCE LOCATION
Follow the general guidelines set out in paragraph 1.1 to the letter. Be aware that the flooring of the installation site
must be capable of withstanding the weight of the appliance and the water contained in it. If this requirement is not
met, it is obligatory to adopt countermeasures (for example, load distribution plate …).
ATTENTION: The room where the appliance is installed must be well ventilated and free
from humidity and salty air. A high level of humidity or saltiness in the room can lead to
the onset of rust or corrosion which will not be covered by warranty. The appliance must
be positioned at a minimum safe distance from walls and furnishings. If inflammable
materials are located in the vicinity of the appliance (e.g.: matchboarding, furniture,
curtains, pictures and paintings, sofas) it is mandatory to comply with the minimum
distances illustrated on the side.
If the flooring is made of wood or any other combustible material, it is mandatory to
install a fireproof floor protector plate between the appliance and the floor. Installation in
the vicinity of heat-sensitive materials is only permitted if suitable insulating and fireproof
protection is placed between the object and the appliance (ref. Uni 10683). Failure to
observe this instruction will immediately invalidate the warranty.
The installer must issue a certificate of conformity for the installation which includes the design plans and the following documents:
a) Report containing the type of materials utilised.
b) Project as defined in Article 5 of Ministerial Decree n° 37 22 January 2008.
d) References to existing partial or previous declarations of conformity (e.g. flue outlet).
e) Copy of the certificate of recognition of the professional technical qualifications.
These documents must, by law, be kept together with the installation, use and maintenance manual. The customer is
responsible for verifying, directly or indirectly, that the installation has been carried out to perfection in accordance
with relevant regulations in force. Do not install the appliance in unsuitable rooms such as bedrooms, bathrooms,
garages and/or lock-ups. It is forbidden to place the appliance in environments with an explosive atmosphere.
ATTENTION, the appliance is not simply a household appliance: if the instructions set out in this manual are not
followed and/or if installation of the appliance is not executed perfectly and/or the provisions in force are not strictly
complied with, dangerous conditions could arise for both objects and persons. It is the user’s responsibility to verify
the presence, in the room, of a vent necessary for supplying oxygen to the appliance. It is strictly prohibited to install
the appliance as inset or next to furniture.
4.2 UNPACKING THE APPLIANCE
The appliance is supplied packaged on a pallet; always use trolleys to move the appliance and the appliance must always be in a
vertical position. Before positioning and installing it dismantle the appliance from the pallet as described:
- Remove the cover, the side panels and any fastening screws from the pallet.
- Remove the appliance from the pallet with the aid of a trolley. Given the weight of the appliance, we recommend that this
operation be carried out by two people.
- Check that all the mobile parts are in place; remove the labels and stickers from the glass.
4.3 CONNECTION TO THE FLUE OUTLET
Connection of the appliance to the flue outlet must be carried out in strict compliance with the instructions
contained in this booklet and particularly with those in the dedicated chapter.
A = 800 mm
L = 300 mm
P = 300 mm