9.3.4 CONTROLS PRIOR TO INSTALLING THE APPLIANCE
The user must possess a certificate of conformance for the flue outlet
(Ministerial Decree 22 January 2008, no. 37).
The flue outlet must be built in compliance with UNI 10683.
The smoke exhaust illustrated in the figure on the side is the best solution
required to ensure that the flue gases are discharged. If you prefer to exhaust
the smoke from the roof insert a union tee with inspection cap, connecting
brackets suitable for the height of the flue outlet, flashing that crosses the roof
and chimney cap to protect against bad weather conditions.
If you decide to use the classic masonry exhaust provide a union tee with
inspection cap and suitable supporting brackets. If the flue outlet is too big it is
necessary to insert a stainless steel or porcelain-coated steel tube with
suitable diameter.
Seal area where the inlet and outlet part of the smoke exhaust meets the wall.
It is strictly forbidden to apply mesh to the end of the outlet tube , as it could
cause the appliance to malfunction.
If the smoke tube is installed in a fixed position it is advisable to provide
inspection openings for clean-out purposes especially in the horizontal
sections.
See the diagram. These openings are essential to allow for the removal of ash
and unburned products which tend to accumulate along the discharge path.
Seal the fittings with red silicone (resistant to 350°C).
LEGENDA
KEY
COMIGNOLO E CANNA FUMARIA SECONDO
NORMA UNI 10683
CHIMNEY CAP AND FLUE OUTLET ACCORDING
TO UNI 10683 STANDARD
2 - 3 metri MAX
2 -3 metres MAX.
Pendenza non inferiore al 5%
Minimum slope 5%
ALTEZZA SUPERIORE A 4 m
HEIGHT MORE THAN 4 m.
Tutte le tubazioni devono essere termicamente
isolate
All the pipes must be thermally insulated
ISPEZIONE
INSPECTION
The outer casing of the tube must be made with insulating material (mineral wool, ceramic fiber) or use pre-insulated tubing.
THE FLUE OUTLET MUST BE USED ONLY FOR THE APPLIANCE.
It must be possible to inspect and remove all the smoke tube sections for clean-out purposes.
ATTENTION: if the flue outlet is not sufficiently insulated and /or if it is too long it could generate condensation. It is
advisable to provide a condensation drain near the smoke outlet of the appliance. The appliance must always and
only be installed in a single flue outlet system dedicated exclusively to the appliance.
If the generator is connected to a non-compliant flue system the appliance could rapidly deteriorate due to an
abnormal, continuous overheating: in this case the damaged parts will not be covered by warranty.
IN THE EVENT OF A FIRE IN THE CHIMNEY CLOSE ALL THE AIR PASSAGES AND CALL THE FIRE BRIGADE IMMEDIATELY
Summary of Contents for Bosky 30 EVO
Page 2: ...Page 1 Installation use and maintenance guide BOSKY 30 F30 EVO BOSKY COUNTRY 30 F30 EVO ...
Page 38: ...Page 37 Installation use and maintenance guide BOSKY 30 F30 EVO BOSKY COUNTRY 30 F30 EVO ...
Page 40: ...Page 39 Installation use and maintenance guide BOSKY 30 F30 EVO BOSKY COUNTRY 30 F30 EVO ...
Page 42: ...Page 41 Installation use and maintenance guide BOSKY 30 F30 EVO BOSKY COUNTRY 30 F30 EVO ...