Installation, use and maintenance guide
COMPACT S22
–S26–S32 EVO5
Page
6
ENG
2 – TECHNICAL CHARACTERISTICS
M.U.
COMPACT S22
EVO5
COMPACT S26
EVO5
COMPACT S32
EVO5
Height
mm
1,373
1,373
1,373
Depth
mm
866
866
866
Width
mm
621
621
621
Empty weight
Kg
265
265
265
Firebox power Min. / Max. *
kW
6.4 / 22.9
6.4 / 26.2
6.4 / 31.7
Thermal output to water Min / Max *
kW
5.9 / 21.4
5.9 / 24.4
5.9 / 29.4
Min. / Max. * consumption
kg/h
1.4 / 4.8
1.4 / 5.6
1.4 / 6.7
Run time at reduced /rated power *
h
46 / 13
46 / 11
46 / 9
Boiler class
5
5
5
Ø smoke exhaust pipe
mm
100
100
100
Min. draught at rated power
Pa - mbar
10
– 0.10
10
– 0.10
10
– 0.10
Min. draught at reduced power
Pa - mbar
10
– 0.10
10
– 0.10
10
– 0.10
Pellet tank capacity*
kg
65
65
65
Water content
l
34
34
34
Minimum working pressure
bar - Pa
1.0
– 100,000
1.0
– 100,000
1.0
– 100,000
Maximum operating pressure
bar - Pa
2.5
– 250,000
2.5
– 250,000
2.5
– 250,000
Average smoke temperature at rated power *
°C
106
115
129
Average smoke temperature at reduced
power *
°C
57
57
57
Max delivery water temperature
°C
80
80
80
Min water return temperature
°C
55
55
55
Smoke flow at rated power *
g/sec
13.4
15.1
16.6
Smoke flow at reduced power *
g/sec
7.2
7.2
7.2
Efficiency at rated power *
%
93.5
93.2
92.8
Efficiency at reduced power *
%
90.9
90.9
90.9
CO at rated power with 10% O
2
*
mg/m³
32
28
21
CO at reduced power with 10% O
2
*
mg/m³
318
318
318
Power supply voltage and frequency
V
– Hz
230 - 50
230 - 50
230 - 50
Electrical consumption at Rated power ****
W
70
70
96
Electrical consumption at Reduced power
****
W
50
50
55
Electrical consumption in standby
W
3
3
3
Loss of load - water side at 10K
mbar
80.9
80.9
80.9
Loss of load - water side at 20K
mbar
323.6
323.6
323.6
Heatable volume **
m³
570
650
790
Noise level ***
db
38
38
38
* All the data are based on the appliance fuelled with EN14961-2 standard type-approved pellets.
** Important: take into consideration the fact that the heatable volume is greatly influenced by the insulation of the house,
i.e. the energy class of the building and by the position of the appliance in the planimetry of the house. The indicated
values, therefore, can vary considerably.
*** Test carried out at reduced power with sound level meter at a distance of 3m.
**** The value does not take into account the electricity consumption of the circulating pump, as it depends on the
pressure loss in the plumbing system.