Installation, use and maintenance guide
COMPACT SLIM S25 EVO
Page
31
ENG
When is it important to use the THERMO ACS function?
In systems configured like the nearby diagram, where the appliance is connected
directly to a domestic hot water boiler tube and to the system.
When using this function the generator starts up automatically when the boiler tube is
running out of heat. Once the boiler tube is satisfied, the appliance switches the 3-
way valve to provide heat to the system.
We recommend installing a chronothermostat to prevent the appliance from being
stressed by uncontrolled ON and OFF cycles (see para. 7.2)
When is it important to use the THERMO ACS function together with the
THERMOCONTROL function?
In systems configured like the nearby diagram, where the appliance is installed in a
system fitted with both a boiler tube and a puffer.
Activate the THERMOCONTROL function to control the puffer and the THERMO
ACS function to control the boiler tube. With this logic the appliance controls the
ON/OFF cycles automatically according to the heat requests from both the puffer and
the boiler tube. Precedence is always given to the boiler tube, and once satisfied, the
appliance switches the 3-way valve and diverts the heat to the puffer and when it is
satisfied it switches OFF.
When is it important to use the THERMO ACS function together with the
TAMBIENT function?
In systems configured like the nearby diagram, where the appliance is connected
directly to a domestic hot water boiler tube and to the system.
When using this function the generator starts up automatically when the boiler
tube is running out of heat.
Once the boiler tube is satisfied, the appliance gives consent for the 3-way valve
to switch over in order to supply the system with heat. When the room
temperature is satisfied the appliance turns to the OFF position, and waits for the
next request for heat from the boiler tube or the room.
6.10 OPERATION OF THE GENERATOR
6.10.1 DESCRIPTION OF THE OPERATING STAGES
START:
has a duration of approx. 20 minutes, during this phase the
appliance is programmed to light the flame. The appliance will not
accept power variations in the firebox. If the appliance does not start
up correctly it could be due to one of the following factors:
cleanliness of the generator, smoke exhaust particularly cold, sudden
surges and drops in the electric power supply, fuel is too moist or
does not comply with the specifications.
WORK
: the duration depends on the ability of the system to receive heat. The generator's operating status is displayed. During this
stage the brazier cleaning mechanism “Pellet Power”, that is, the
device
installed inside the brazier, moves in timed mode.
OFF:
has a duration of approx. 25 minutes. In this phase the
appliance is switched off until a new "on" phase is initiated. The aim is
to
make the pellet embers in the brazier die out. A few seconds aftet the
activation of the OFF cycle the brazier cleaning mechanism “Pellet
Power”, that is, the device installed inside the brazier, moves in continuous mode. After approx. 25 minutes the appliance goes to
standby and the brazier cleaning m
echanism “Pellet Power” stops.
ATTENTION:
It is recommended to verify at least once a month that when the appliance is in OFF mode in the time
interval specified above, the brazier cleaning mechanism “Pellet Power” operates in continuous mode to clean the
brazier.
STOP:
If the temperature of the appliance exceeds the 80°C threshold, the momentary shut off, identified as STOP, is activated.
ATTENTION: The STOP phase allows the generator to begin a new START phase only when the temperature drops below 58°C.
ATTENTION: The STOP mode must be considered an overtemperature pre-allarm, and therefore cannot be considered a normal
operating stage.
WAIT ON
: when the appliance is restarted while hot where the water temperature is higher than 63°C the appliance does not start
immediately, but the circulating pump will still be active. The message WAIT ON appears on the display. A new startup procedure
will not begin until the temperature drops to 58°C. The text START will appear on the screen.
Legenda
Key
Temperatura acqua
generatore (°C)
Generator water
temperature (°C)
Avvio
Start
Lavoro
Running
Off
Off
Tempo (minuti)
Time (minutes)
Il presente disegno è di proprietà esclusiva di THERMOROSSI S.p.A.. La riproduzione totale e/o parziale e la divulgazione a terzi, senza nostro esplicito consenso scritto, verrà perseguito secondo i termini di legge in vigore.
Scala
Locazione file
Data
F
irm
a
Foglio
Note
Materiale
Prodotto
Sviluppo
1/1
TEL. 0445-741310 - FAX 0445-741657
Via Grumolo, 4 - 36011 ARSIERO (Vicenza) - ITALY
S.p.A.
Spessore
Approv
.
D
at
a
appro
v
.
Formato
6_10
Cod.
Disegnatore
Volume
Peso
Colore
Revisione
Descrizione
Revisione
Autore
Data
Descrizione
LAMIERA
Il fornitore è responsabile della corretta realizzazione del
particolare come indicano le viste di progetto; lo sviluppo
piano deve essere verificato ed eventualmente modificato dal
fornitore in funzione delle macchine di piegatura che
andranno a realizzare il particolare.
STAMPI E FUSIONI
É obbligo da parte del fornitore, prima di
realizzare qualsiasi attrezzatura, fornire a
THERMOROSSI S.p.A. i file
tridimensionali dei particolari definitivi
X
Te
m
perat
u
ra
acqu
a
ge
nerat
o
re
(°
c
)
Avvio
Lavoro
OFF
tempo(minuti)
Potenza di funzionamento
5
4
3
2
1
61°c
65°c
Intervallo modulazione con T max 65°c
STOP
80°c
Potenza di funzionamento
5
4
3
2
1
61°c
70°c
Intervallo modulazione con T max 70°c
STOP
80°c
Potenza di funzionamento
3
61°c
STOP
80°c
Summary of Contents for COMPACT SLIM S25 EVO