Installation, use and maintenance guide
COMPACT SLIM S25 EVO
Page
48
ENG
THE APPLIANCE
ENTERS ALARM
MODE A FEW
MINUTES AFTER
THE START
SEQUENCE HAS
ENDED
DELAYED START BECAUSE THE SCREW FEEDER WAS EMPTY
THE
“FAILED START – CLEAN BURNER”
ALARM IS SHOWN ON THE
DISPLAY
CLEAN THE BRAZIER AS INDICATED IN THIS USE AND
MAINTENANCE GUIDE, THEN FILL UP THE TANK WITH
PELLETS
START UP HAS BEEN GREATLY DELAYED BECAUSE THE BRAZIER
IS DIRTY:
THE
“FAILED START – CLEAN BURNER”
ALARM IS SHOWN ON THE
DISPLAY
CLEAN THE BRAZIER AS INDICATED IN THIS USE AND
MAINTENANCE GUIDE
THE APPLIANCE
DOES NOT START
UP
THE SPARK PLUG IS NOT WORKING
THE
“FAILED START – CLEAN BURNER”
ALARM IS SHOWN ON THE
DISPLAY
CONTACT THE TECHNICAL ASSISTANCE SERVICE FOR
REPLACEMENT OF THE SPARK PLUG
THE PELLET TANK OR SCREW FEEDER IS EMPTY
THE
“FAILED START – CLEAN BURNER”
ALARM IS SHOWN ON THE
DISPLAY
CLEAN THE BRAZIER AS INDICATED IN THIS USE AND
MAINTENANCE GUIDE, THEN FILL UP THE TANK WITH
PELLETS
EXCESSIVE DRAUGHT IN THE FLUE OUTLET
THE
“FAILED START – CLEAN BURNER”
ALARM IS SHOWN ON THE
DISPLAY
HAVE THE FLUE OUTLET DRAUGHT CHECKED
THE HOLE OF THE SPARK PLUG SEAT IS CLOGGED WITH
COMBUSTION RESIDUES
CLEAN THE BRAZIER AS INDICATED IN THIS USE AND
MAINTENANCE GUIDE
THE
TEMPERATURE OF
THE APPLIANCE
DOES NOT RISE
ROOM TEMPERATURE THERMOSTAT SET TOO LOW, APPLIANCE
OPERATES INTERMITTENTLY
OPERATE FOR LONGER PERIODS OR AT A HIGHER POWER
LEVEL BY SETTING A HIGHER ROOM TEMPERATURE
SURFACE AREA TO HEAT IS TOO BIG OR TOO COLD
CEILINGS ARE VERY HIGH OR WITH HIGH DISPERSION OF HEAT
OPERATE FOR LONGER PERIODS OR AT A HIGHER POWER
LEVEL BY SETTING A HIGHER ROOM TEMPERATURE. IF
NECESSARY CONTACT A HEAT TECHNOLOGY EXPERT TO
MAKE A CORRECT CALCULATION OF THE REQUIRED POWER
POOR QUALITY PELLETS
CHANGE TO AN APPROVED TYPE OF PELLET AS INDICATED
IN THIS USE AND MAINTENANCE GUIDE
THE APPLIANCE IS
SWITCHED OFF
AND THERE ARE
SOME UNBURNT
PELLETS IN THE
BRAZIER
PELLETS RUN OUT WHILE THE APPLIANCE IS OPERATING,
THE
“NO PELLET – CLEAN BURNER”
ALARM IS SHOWN ON THE
DISPLAY
CLEAN THE BRAZIER AS INDICATED IN THIS USE AND
MAINTENANCE GUIDE, THEN FILL UP THE TANK WITH
PELLETS
EXCESSIVE DRAUGHT IN THE FLUE OUTLET
THE
“NO PELLET – CLEAN BURNER”
ALARM IS SHOWN ON THE
DISPLAY
HAVE THE FLUE OUTLET DRAUGHT CHECKED AND IF
NECESSARY MAKE THE APPROPRIATE MODIFICATIONS
THE TIME DOES
NOT REMAIN IN
THE MEMORY
THE BUFFER BATTERY INSTALLED IN THE CONTROL PANEL
FACEPLATE IS DEAD
CONTACT THE TECHNICAL ASSISTANCE SERVICE FOR
REPLACEMENT OF THE BATTERY
THE HOURLY
PROGRAM IS NOT
COMPLIED WITH
THE USER HAS NOT ENABLED IT
PRESS THE CLOCK BUTTON TO ENABLE IT AS INSTRUCTED
IN THIS USE AND MAINTENANCE GUIDE
THE BUFFER BATTERY INSTALLED IN THE CONTROL PANEL
FACEPLATE IS DEAD
CONTACT THE TECHNICAL ASSISTANCE SERVICE FOR
REPLACEMENT OF THE BATTERY
AN INCORRECT PROGRAMMING PROCEDURE WAS CARRIED OUT
VERIFY THE TIMES SET IN THE CHRONO FUNCTION
THE BRAZIER
CLEANING
MECHANISM IS
WORN
POOR QUALITY PELLETS CONTAINING CHEMICAL BINDERS
CHANGE TO AN APPROVED TYPE OF PELLET AS INDICATED
IN THIS USE AND MAINTENANCE GUIDE
NOT ENOUGH OXYGEN FOR COMBUSTION
CONTACT TECHNICAL ASSISTANCE FOR REGULATION OF
THE COMBUSTION
THE BRAZIER
CLEANING
MECHANISM DOES
NOT WORK
THE MOTOR OF THE BRAZIER CLEANING MECHANISM IS FAULTY
CONTACT TECHNICAL ASSISTANCE FOR REPLACEMENT OF
THE MOTOR
THE APPLIANCE IS
IN STOP MODE
ZONE VALVES ARE PRESENT IN THE SYSTEM AND THEY ARE ALL
CLOSED
OPEN AT LEAST ONE ZONE IN ORDER TO ENSURE
ADEQUATE DISSIPATION OF THE HEAT PRODUCED
THE CIRCULATING PUMP DOES NOT WORK
CONTACT OUR TECHNICAL ASSISTANCE SERVICE FOR
REPLACEMENT OF THE PART
THE APPLIANCE IS SET AT A POWER LEVEL THAT IS TOO HIGH
AND THE SYSTEM CANNOT ABSORB THE HEAT PRODUCED
SET THE APPLIANCE IN AUTOMATIC MODE
IF THE REMEDIES SUPPLIED HERE DO NOT SOLVE THE PROBLEM YOU HAVE ENCOUNTERED OR IF YOU REQWUIRE SPARE PARTS CONTACT AN
AUTHORISED TECHNICAL SUPPORT CENTRE
Summary of Contents for COMPACT SLIM S25 EVO
Page 2: ......
Page 3: ......
Page 43: ...Installation use and maintenance guide COMPACT SLIM S25 EVO Page 40 ENG FIGURE 8 FIGURE 9 ...