CLEANING AND MAINTENANCE
CLEANING AND MAINTENANCE
CLEANING AND MAINTENANCE
CLEANING AND MAINTENANCE
CLEANING AND MAINTENANCE
8 . 1
8 . 1
8 . 1
8 . 1
8 . 1
F O R E W O R D
F O R E W O R D
F O R E W O R D
F O R E W O R D
F O R E W O R D
Before commencing any operation disconnect the appliance from the electric power outlet. Your ECOTHERM pellet heater does not
require any special maintenance; simply adhere to the simple and basic but regular controls and general cleaning. This will guarantee
regular operation and optimal output at all times. If the product is unused for a prolonged period of time it is mandatory to inspect the
smoke channel and outlet to ensure that there are no obstructions before use. It is necessary to accurately follow the directions given
below: Otherwise severe damages may occur for the product, the installation, objects and the people who use the generator.
CAUTION: The manufacturer denies all responsibility for the life of the electrical heater if subjected to excessive start ups. The
manufacturer recommends setting a suitable room temperature value in the chronothermostat in order to prevent this possibility.
CAUTION: Use N.O. (normally open) contacts for the connection to the chronothermostat. Contact 1-3 of the chronothermostat
mod. "Perry".
CAUTION: In the event of connections to the chronothermostat Thermorossi shall not be held responsible for the insert not starting
up, smoke leaks, breakage of the lighting component. In the event of a programmed cycle on always ensure that the brazier is
clean and seated correctly in its lodging.
7
ADDITIONAL ROOM TEMPERATURE THERMOSTAT
(not supplied)
ADDITIONAL CHRONOTHERMOSTAT
(not supplied)
The control panel ensures that your heater is provided with all the required programming and tempe-
rature adjustment functions:
Two gland nuts are fitted to the back of the heater near the power point.
They refer to two operating modes:
à
With the room temperature thermostat.
à
With the chronothermostat or modem.
Simply connect the additional room temperature thermostat to the gland nut on the heater marked
"Room Temperature Thermostat" or the additional chronothermostat to the gland nut on the heater marked "Chronothermostat - modem".
Use only contacts 1 and 2.
Contacts 1-2 are defined as "CLEAN" contacts and they must never be fed with 220 V. If the board is energised with 220V or
voltages exceeding 6 V the control board will be permanently damaged and will not be covered by the GUARANTEE.
7.1 OPERATING WITH THE ADDITIONAL ROOM TEMPERATURE THERMOSTAT (NOT SUPPLIED )
An additional room temperature thermostat can be installed by connecting it to the cable gland marked “THERMOSTAT” at the back of the
heater. The operating principle is as follows:
-
When the room temperature reaches the set temperature (only during the RUNNING phase) the thermostat closes the contact and the heater
shifts to the minimum room fan speed and minimum combustion power. By using the room temperature thermostat the heater does not shut
down, therefore electrical energy consumption is kept to the minimum and the heater has a longer life.
-
When the room temperature drops the thermostat opens the contact and the heater returns to its original position in terms of thermal power
and ventilation.
-
In this position it is not possible to start up the heater automatically or shut it down automatically.
CAUTION: N.C. (normally closed) contacts must be used for the connection to the additional room temperature thermostat.
Contacts 1-2 of the chronothermostat mod. "Perry".
7.2 OPERATING WITH THE ADDITIONAL CHRONOTHERMOSTAT (NOT SUPPLIED )
As an alternative to the room temperature thermostat, a chonothermostat can be installed by connecting it to the cable gland marked
“CHRONOTHERMOSTAT” fitted to the back of the heater. Using this outlet when the chronothermostat contact closes the START cycle starts,
whereas when the contact opens the OFF cycle starts. The operating level at start up (combustion power - fan speed ) is the same as the
level used before the last time the heater shut down. This operation can also occur by adjusting its room temperature. Once the desired tem-
perature set on the chronothermostat is reached the contact opens and executes the shut down cycle. Similarly when the room temperature
drops below the set temperature the contact closes and the START cycle starts. If an unsuitable room temperature value is selected the
heater will be subjected to continual ON-OFF cycles, consequently the increased number of start ups will result in greater consumption of
electrical energy. The chronothermostat can be used to program temperatures, times and dates for the ON-OFF cycles. It is therefore
possible to program a momentary shutting down of the heater according to the room temperature.