CLEANING AND MAINT
AND MAINT
AND MAINT
AND MAINT
AND MAINTAINING
AINING
AINING
AINING
AINING THE HEA
THE HEA
THE HEA
THE HEA
THE HEAT E R
T E R
T E R
T E R
T E R
•
EVERY DAY remove all combustion residues from the brazier then remount the brazier and the catalyst (Figure 1 shows a clean brazier).
Caution: make sure, before every start up, that the brazier is clean and if necessary also thoroughly clean the burner with a suction unit.
Take particular care to clean the area near the spark plug : this will guarantee the correct operation of the appliance .
•
EVERY 3 DAYS lift and drop the tube scraper rods several times (Figure 2)
•
EVERY 5 DAYS clean the room air filter located at the back of the heater (Figure 11).
•
EVERY WEEK empty the ash pan "V" of all residual ash (figure 9).
•
EVERY WEEK vacuum the residual ash from the compartment "V1" under the brazier.To facilitate vacuuming remove the blade and brazier
(Figure 10).
•
EVERY 2 WEEKS clean the smoke exhaust "T" at the heater inlet .
•
EVERY MONTH undo the screws to inspect and clean vent A1 shown in Figure 5; to access this area remove the lower covering as
indicated in Figures 3 and 4. In the Easy model press the 2 side folds of the lower cover inwards to extract it.
•
EVERY MONTH check that the smoke exhaust is free from fly ash deposits, particularly in the initial sections.
•
EVERY MONTH vacuum the ash deposited on the bottom of the tank (when the tank is empty).
•
AT THE END OF THE WINTER SEASON OR WHENEVER NECESSARY we recommend thoroughly cleaning the Ecotherm firebox, using
brushes and vacuum cleaner.
•
TWICE A YEAR clean the smoke exhaust, including the flue outlet. clean the inside of the combustion chamber behind the tube bundle
(Figures 6,7,8). To access this area lift the shell (Figures 6 , 7) by rotating it as shown in Figure 8: now clean the area with a suction device.
A vacuum device simplifies the cleaning procedure. Use a damp cloth or a
scrunched up piece of newspaper, dampened and rolled in the ash, to wipe
the glass until it is perfectly clean. Do not clean the glass while the heater
is operating.
The glass remains reasonably clean if the catalyst - deviator blade is installed
correctly in the brazier as shown in figure 9. The insert must be completely
cooled down before the side panel can be cleaned with a soft cloth and
water.
Caution: A daily deposit of soot and combustion residues on the glass is
quite normal. It is normal for the ash to fall to the floor when the door is
opened.