If another heater is installed in the vicinity of this heater then the
code selector in both the power board and the handheld radio
control (optional) will have to be reset; this is necessary to prevent
interferences with the operation of the two heaters. The code set
in out products is standard. If you wish to alter the transmission
code act on the selectors in the power board and the handheld
radio control, making sure that they are set identically (see dedicated
paragraph).
11A ELECTRICAL WIRING FOR MODEL
11A ELECTRICAL WIRING FOR MODEL
11A ELECTRICAL WIRING FOR MODEL
11A ELECTRICAL WIRING FOR MODEL
11A ELECTRICAL WIRING FOR MODEL
Ventilatore 1 A
M
IC
RO
PR
OC
ES
SO
RE
Fu
si
bi
le
1
A
2
ON
1
PRESSOSTATO
TERMOSTATO 95°C
TERMOSTATO 42°C
2
1
4
AMBIENTE
VENTILATORE
MANUALE
TERMOSTATO RIARMO
PELLETS
MOTORE CARICO
ASPIRATORE FUMI
Fu
si
bi
le
3
,15
A
Fusibile
22
0-
24
0V
50
H
z
RESISTENZA
RADIOCOMANDO PALMARE
SCHEDINA RICEVITORE
4
1
2
1-4 Termostato Ambiente
1-2 Cronotermostato
Per i modelli ECOTHERM 3001 THERMOCOMFORT EASY,METALCOLOR,CERAMICA
SE
LE
TT
OR
E
C
OD
IC
I
PE
R
RA
DI
OC
OM
AN
DO
3
4
ON
3
4
2
1
1 0
1 0
1 0
1 0
1 0
ALARMS
ALARMS
ALARMS
ALARMS
ALARMS
The heater is programmed to communicate 3 fundamental alarms. The alarms are listed below:
AL PE
: is communicated when the temperature during the On mode drops below 42 °C.
This indicates that the heater is switching off due to lack of pellets.
AL AC
: is communicated if after the start up phase the temperature does not rise above 42°C.
AL OP
: this occurs when the smoke outlet is partially blocked.
In order to set the alarms to zero, the feed to the heater must be turned off and restored using switch 0-1 on the back of the heater.
SELETTORE CODICI PER RADIOCOMANDO
PALMARE GESTITO VIA ONDE RADIO
2
1
ON
3
4
2
ON
1
3
4
K E Y
Radio wave-controlled code selector for
handheld radio control
Code selector for handheld radio
control
Thermostat 42°/95°C
Pressure switch
Room temperature thermostat
Chronothermostat
Handheld radio control receiver card
Heater
Smoke suction unit
Manual reset thermostat
Pellet feed motor
Room fan
Microprocessor
Fan fuse 1A
Fuse 1 A / 3,15 A
For models ECOTHERM3001,
THERMOCOMFORT, EASY,
METALCOLOR, CERAMIC
LEGENDA
Selettore codici per radiocomando
palmare gestito via onde radio
Selettore codici per radiocomando
Termostato 42°/95°C
Pressostato
Termostato ambiente
Cronotermostato
Schedina ricevitore radiocomando
palmare
Resistenza
Aspiratore fumi
Termostato riarmo manuale
Motore carico pellets
Ventilatore ambiente
Microprocessore
Fusibile ventilatore 1A
Fusibile 1 A / 3,15 A
Per i modelli ECOTHERM3001,
THERMOCOMFORT, EASY,
METALCOLOR, CERAMICA
Summary of Contents for ECOTHERM 5000
Page 16: ...pg 16 ...
Page 17: ...pg 17 ...