pg. 23
THE HEATER ACCUMULATES PELLETS IN
THE BRAZIER
SEE POINT
“PROBLEM-CAUSE-SOLUTION”
“THE
APPLIANCE A CCUMULATES PELLETS IN THE
BRAZIER WHILE OPERATING”
NO CAUSE
CLEAN THE GLASS MORE OFTEN
THE GLASS IS COVERED IN BLACK SOOT
THE BLADE POSITION IS NOT CORRECT/NO
BLADE
POSI TION THE BLADE CORRECTLY/MOUNT THE
BLADE
ABSENCE OF FLOW OF VENTILATION AIR
THE VENTILATION FILTER IS DI RTY
CLEAN THE FILTER LOCATED AT THE BACK OF THE
HEATER
THE HEATER OPERATES AT INTERVALS.
THE HEATER MUST OPERATE FOR MORE HOURS
WITH MORE POWER
THE ROOM IS TOO LARGE, THE WALLS ARE
COLD
SEPARATE THE SPACES.
THE HEATER SHOULD OPERATE FOR MORE HOURS
AND WITH MORE POWER
IT DOES NOT WARM UP
CEILINGS TOO HIGH OR PRESENCE OF
STAIRS
THAT
DISPERSE
THE
HEAT
ELSEWHERE.
SEPARATE THE SPACES.
THE HEATER SHOULD OPERATE FOR MORE HOURS
AND WITH MORE POWER
THE APPLIANCE IS OFF BUT THERE ARE UNBURNT
PELLETS IN THE BRAZIER
THE TANK IS EMPTY
EMPTY THE BURNER AND FILL UP THE TANK.
THE PROGRAMMING AND/ OR TIME DO/DOES NOT
REMAIN IN THE MEMORY
THE
BUFFER BATTERY TYPE
CR2032
INSTALLED I N THE CONTROL PA NEL IS
EXHAUSTED
REPLACE THE BATTERY
THE HEATER EXECUTES RANDOM COMMANDS OR
RANDOMLY VARIES THE VENTILATION LEVEL AND
THE COMBUSTION LEVEL
NEARBY THERE IS ANOTHER THERMOROSSI
HEATER MODEL THERMOCONFORT WITH
THE OPTIONAL RADIO CONTROL
CHANGE THE CODE SELECTOR