pg. XV
At
te
nz
io
ne
:
ch
iu
de
re
t
ut
ti
i f
or
i
no
n
us
at
i d
el
p
uf
fe
r
So
nd
a
2
So
nd
a
1
Tu
bi
d
i c
ol
le
ga
m
en
to
a
cc
um
ul
i
At
te
nz
io
ne
:
ch
iu
de
re
t
ut
ti
i f
or
i
no
n
us
at
i d
el
p
uf
fe
r
Va
lv
ol
a
m
is
ce
la
tr
ic
e
3
vi
e
te
rm
os
ta
tic
a
55
°c
Va
lv
ol
a
sa
ra
ci
ne
sc
a
(d
a
pa
rz
ia
liz
za
re
in
fu
nz
io
ne
d
el
le
p
er
di
te
d
i c
ar
ic
o
de
ll'
im
pi
an
to
Th
er
m
op
uf
fe
r
ag
gi
un
tiv
o
Va
so
d
i e
sp
an
si
on
e
ch
iu
so
pu
nt
o
fis
so
.
Va
lv
ol
a
a
3
vi
e
Th
er
m
oc
el
l
o
Th
er
mo
pu
ff
er
Ci
rc
ol
at
or
e
Va
lv
ol
a
di
n
on
r
ito
rn
o
Va
lv
ol
a
3
vi
e
ma
nu
al
e
M
an
da
ta
c
al
da
ia
Ri
sc
al
da
m
en
to
p
av
im
en
to
Ra
di
at
or
i
Ri
to
rn
o
ca
ld
ai
a
Sa
ra
ci
ne
sc
a
4 . 7
4 . 7
4 . 7
4 . 7
4 . 7
SCHEMA
SCHEMA
SCHEMA
SCHEMA
SCHEMATIC DRA
TIC DRA
TIC DRA
TIC DRA
TIC DRAWING OF
WING OF
WING OF
WING OF
WING OF TYPICAL HYDRA
TYPICAL HYDRA
TYPICAL HYDRA
TYPICAL HYDRA
TYPICAL HYDRAULIC CIR
ULIC CIR
ULIC CIR
ULIC CIR
ULIC CIRCUIT FOR H20 / COMP
CUIT FOR H20 / COMP
CUIT FOR H20 / COMP
CUIT FOR H20 / COMP
CUIT FOR H20 / COMPA
A
A
A
ACT +
CT +
CT +
CT +
CT +
THERMOCELL (OR
THERMOCELL (OR
THERMOCELL (OR
THERMOCELL (OR
THERMOCELL (OR THERMOPUFFER) +
THERMOPUFFER) +
THERMOPUFFER) +
THERMOPUFFER) +
THERMOPUFFER) + ADDITION
ADDITION
ADDITION
ADDITION
ADDITIONAL
AL
AL
AL
AL THERMO HIGH
THERMO HIGH
THERMO HIGH
THERMO HIGH
THERMO HIGH TEMPERA
TEMPERA
TEMPERA
TEMPERA
TEMPERATURE
TURE
TURE
TURE
TURE
HEA
HEA
HEA
HEA
HEATING
TING
TING
TING
TING AND L
AND L
AND L
AND L
AND LO
O
O
O
OW
W
W
W
W TEMPERA
TEMPERA
TEMPERA
TEMPERA
TEMPERATURE HEA
TURE HEA
TURE HEA
TURE HEA
TURE HEATING
TING
TING
TING
TING .....
CAUTION:
The system operating pressure must always be above the expansion tank preload:
2 bar for the expansion tank 1,5 bar.
CAUTION:
The Thermocell must also be connected only to 220V - 50Hz power supply"; the adjustments of Sensor S1 and Sensor S2
must be controlled by the heater / boiler and not by the Thermocell electric panel.
For this purpose connect 2 thermocouples (optional code no. 60010695) to the cable clamps of Sensor 1 and Sensor 2" of
the generator.
CAUTION:
Sensor S1 must be set at 65°C (over 65°C it switches off the boiler ). Sensor S2 must be set at 40 - 45°C (under 40 - 45°C it
switches on the boiler ).
K E Y
Radiators
Underfloor heating
Caution: close all the
holes not used by the
puffer
Sensor 1 / 2
Connection tubes to
puffers
Additional Thermopuffer
Vaso di espansione
chiuso
Thermocell or
Thermopuffer
Boiler delivery
Boiler return
Three-way thermostatic
mixing valve, fixed point
Circulating pump
Manual three-way valve
Gate valve
gate valve (throttle
according to pressure
drop in the system)
Three-way valve
Nonreturn valve
Caution: it is mandatory to earth the heater / boiler. If this instruction is not observed serious damage, which is not
covered by warranty, will result to the body of the heater / boiler. Have an electrician check the earthing. There
must be no electric potential (volts) between the earth of the generator and the actual earth of the plant. To prevent
electrochemical corrosion of the boiler body do not use galvanised pipes and fittings. Dedicated ground wires must
be used to ground all other materials .
LEGENDA
Radiatori
Riscaldamento
pavimento
Attenzione: chiudere tutti
i fori non usati del puffer
Sonda 1 / 2
Tubi di collegamento
accumuli
Thermopuffer aggiuntivo
Vaso di espansione
chiuso
Thermocell o
Thermopuffer
Mandata caldaia
Ritorno caldaia
Valvola miscelatrice 3 vie
termostatica punto fisso
Circolatore
Valvola 3 vie manuale
Saracinesca
Valvola saracinesca (da
parzializzare in funzione
delle perdite di carico
dell'impianto)
Valvola a 3 vie
Valvola di non ritorno