Page 36
Installation, use and maintenance guide
Pellet Air 11 Stove body
10.3.2 FLUE OUTLET / FLUE SYSTEM COMPONENTS
LEGENDA
KEY
COMIGNOLO E CANNA FUMARIA SECONDO NORMA
UNI 10683
CHIMNEY CAP AND FLUE OUTLET
ACCORDING TO UNI 10683 STANDARD
TUTTE LE TUBAZIONI DEVONO ESSERE
TERMICAMENTE ISOLATE
ALL THE PIPES MUST BE THERMALLY
INSULATED
ISPEZIONE
INSPECTION
ALTEZZA SUPERIORE A 5 metri
HEIGHT MORE THAN 5 metres
Pendenza 3% - 5%
Slope 3-5%
2-3 metri MAX
2-3 metres MAX.
INTERNO
INTERNAL
ESTERNO
EXTERNAL
LASTRA DI COPERTURA
COVER SLAB
LAMIERA DI ACCIAIO A TENUTA STAGNA
WATERTIGHT STEEL SHEET
Every chimney must have minimum
number of components as laid down by
standard UNI EN 10683 which are also
indicated in the figure on the left.
Wall outlets, that is outlets installed on
the outer front wall without the use of a
chimney/flue outlet /flue pipe to convey
the combustion products to the roof, are
strictly prohibited.
Components and
accessories of a chimney
Keys
1 Chimney
2 Flow path
3 Smoke discharge tube
4 Thermal insulation
5 External wall
6 Outer lining
7 Flue outlet section
8 Multiwall chimney
9 Connector
10 Flue pipe
11 Heat generator
ISPEZIONE
INTERNO
ESTERNO
ISPEZIONE
COMIGNOLO E
CANNA FUMARIA
SECONDO NORMA
UNI 10683
LASTRA DI
COPERTURA
LAMIERA DI ACCIAIO
A TENUTA STAGNA