Installation, use and maintenance guide
PIDRA 18
Page
52
ENG
CEILINGS ARE VERY HIGH OR WITH HIGH
DISPERSION OF HEAT
LEVEL BY SETTING A HIGHER ROOM TEMPERATURE. IF
NECESSARY CONTACT A HEAT TECHNOLOGY EXPERT TO
MAKE A CORRECT CALCULATION OF THE REQUIRED POWER
POOR QUALITY PELLETS
CHANGE TO AN APPROVED TYPE OF PELLET AS INDICATED IN
THIS USE AND MAINTENANCE GUIDE
THE APPLIANCE IS SWITCHED
OFF AND THERE ARE SOME
UNBURNT PELLETS IN THE
BRAZIER
PELLETS RUN OUT WHILE THE APPLIANCE IS
OPERATING,
THE
“NO PELLET – CLEAN BURNER”
ALARM IS
SHOWN ON THE DISPLAY
CLEAN THE BRAZIER AS INDICATED IN THIS USE AND
MAINTENANCE GUIDE, THEN FILL UP THE TANK WITH PELLETS
EXCESSIVE DRAUGHT IN THE FLUE OUTLET
THE
“NO PELLET – CLEAN BURNER”
ALARM IS
SHOWN ON THE DISPLAY
HAVE THE FLUE OUTLET DRAUGHT CHECKED AND IF
NECESSARY MAKE THE APPROPRIATE MODIFICATIONS
THE TIME DOES NOT REMAIN
IN THE MEMORY
THE BUFFER BATTERY INSTALLED IN THE CONTROL
PANEL FACEPLATE IS DEAD
CONTACT THE TECHNICAL ASSISTANCE SERVICE FOR
REPLACEMENT OF THE BATTERY
THE HOURLY PROGRAM IS
NOT COMPLIED WITH
THE USER HAS NOT ENABLED IT
PRESS THE CLOCK BUTTON TO ENABLE IT AS INSTRUCTED IN
THIS USE AND MAINTENANCE GUIDE
THE BUFFER BATTERY INSTALLED IN THE CONTROL
PANEL FACEPLATE IS DEAD
CONTACT THE TECHNICAL ASSISTANCE SERVICE FOR
REPLACEMENT OF THE BATTERY
AN INCORRECT PROGRAMMING PROCEDURE WAS
CARRIED OUT
VERIFY THE TIMES SET IN THE CHRONO FUNCTION
THE BRAZIER CLEANING
MECHANISM IS WORN
POOR QUALITY PELLETS CONTAINING CHEMICAL
BINDERS
CHANGE TO AN APPROVED TYPE OF PELLET AS INDICATED IN
THIS USE AND MAINTENANCE GUIDE
NOT ENOUGH OXYGEN FOR COMBUSTION
CONTACT TECHNICAL ASSISTANCE FOR REGULATION OF THE
COMBUSTION
THE BRAZIER CLEANING
MECHANISM DOES NOT WORK
THE MOTOR OF THE BRAZIER CLEANING
MECHANISM IS FAULTY
CONTACT TECHNICAL ASSISTANCE FOR REPLACEMENT OF
THE MOTOR
THE APPLIANCE IS IN STOP
MODE
ZONE VALVES ARE PRESENT IN THE SYSTEM AND
THEY ARE ALL CLOSED
OPEN AT LEAST ONE ZONE IN ORDER TO ENSURE ADEQUATE
DISSIPATION OF THE HEAT PRODUCED
THE CIRCULATING PUMP DOES NOT WORK
CONTACT OUR TECHNICAL ASSISTANCE SERVICE FOR
REPLACEMENT OF THE PART
THE APPLIANCE IS SET AT A POWER LEVEL THAT IS
TOO HIGH AND THE SYSTEM CANNOT ABSORB THE
HEAT PRODUCED
SET THE APPLIANCE IN AUTOMATIC MODE
IF THE REMEDIES SUPPLIED HERE DO NOT SOLVE THE PROBLEM YOU HAVE ENCOUNTERED OR IF YOU REQWUIRE SPARE PARTS CONTACT AN
AUTHORISED TECHNICAL SUPPORT CENTRE