INSTALLATION, USE AND MAINTENANCE GUIDE
POPSTAR 6
– POPSTAR 10
Page
18
ENG
Display
The following information can appear on the display:
Displays the preset
combustion power
, and consequently the pellet consumption
,
by the number of
bars that are
lit up around the flame symbol, using this logic:
One bar lit up:
Minimum combustion power (and therefore with minimum pellet consumption)
Two bars lit:
Second combustion power
Three bars lit:
Third combustion power
Four bars lit:
Fourth combustion power
Five bars lit up:
Maximum combustion power (and therefore with maximum pellet consumption)
No bars lit up:
The appliance is OFF
Displays the preset
ventilation power
, and consequently the room fan speed
,
by the number of
bars that are lit
up around the fan symbol, using this logic:
One bar lit up:
Minimum ventilation power
Two bars lit up:
Second ventilation power
Three bars lit:
Third ventilation power
Four bars lit:
Fourth ventilation power
Five bars lit:
Fifth ventilation power
Six bars lit
:
Maximum ventilation power
Displays the off status of the ventilation, that is, the room fan is disabled. However, if the temperature of the stove
body rises, the fan is forcibly activated and increases the ventilation power as the temperature increases, which
can be seen by the bars that light up around the symbol. Once it has dropped below a certain threshold the room
fan deactivates automatically.
Dashes appear along the top of the display, and each dash corresponds to one day of the week set by the user
(e.g. 1 corresponds to Monday, 2 corresponds to Tuesday… etc.).
The operating status of the appliance appears below these dashes, that is START, OFF or WORK. And the current
time set by the user appears below this word.
The presence in the display of the clock symbol indicates that the CRONO programming has been enabled; if this symbol
does not appear it means that the CRONO programming has been disabled.
5.2 DESCRIPTION OF THE POWER PANEL
The components of the power board are described below:
1) Main switch 0/I.
2) Protection fuse 3.15 A.
3) Electrical power outlet 220V-240V 50Hz.
4) Outlet RJ 45 to connect Wi-Fi module.
5) Test indicator light for pellet feed motor.
The light comes on simultaneously with the activation of the pellet feed motor.
6) Cap for reset thermostat button.
If the reset thermostat overheats stop the pellet feeder. The appliance must
cool down before you can restart the appliance. After verifying and eliminating
the causes of the overtemperature, undo the protective cap and press the
button.
Legenda
Key
DETTAGLIO B
DETAIL B
Emissione:21/07/2020
Revisione:
B
DETTAGLIO B
4
5
6
1
2
3