Alternatively, if you wish to copy the exact same programming for the ON/OFF cycles set for a particular day to the next day simply
press the
Ventilation button
.
For example: if I want to copy all the programmed ON/OFF cycles set for Monday to Tuesday the following screen will appear:
I press the
Ventilation button
once again to copy all the cycles programmed for Tuesday to Wednesday. The following screen will
appear:
Using the same logic we can copy the programmed cycles to the other days.
7) To conclude the programming operations simply press the
Menu Button
to exit the screen, and the initial screen will appear.
ATTENTION: The appliance ignores any ON or OFF command programmed with a value of 00:00
. Consequently
if you do not wish to use an ON or OFF time setting simply set a value of
00:00
. The appliance ignores any ON or OFF
command if the shut off time is set the same as or before the start up time.
ATTENTION:
In the event of a programmed cycle on always ensure that the brazier is clean and in the correct position. Failure to
clean the brazier can reduce and/or affect the life of the spark plug as it would be subjected to high temperatures due
to poor cooling. It is recommended to set ON/OFF cycles times lasting no less than 2 hours, in order to save energy
and for the proper operation of the appliance.
Enabling the programmed cycles:
Back in the initial screen, to enable the appliance to carry out the ON/OFF cycles as programmed simply press the
Clock Button
.
The text CR.ON and the image of a clock will appear on the main screen:
The programmed cycles are now enabled.
When the programmed cycles are enabled (a clock symbol appears on the display) it will not be possible to use an
additional chronothermostat (see dedicated paragraph).
When the programmed cycles are active the operating level at start up will be the same level set before the last time the
machine was shut off.
Disabling the programmed cycles:
To disable the appliance from carrying out the programmed ON/OFF cycles press the
Clock Button
once again. The text CR.OFF
will appear on the display and the clock symbol will disappear. This operation disables the weekly program that has been set by the
user but does not delete or reset the times.
Resetting the programmed cycles:
Moreover, it is possible to reset, in other words delete, all the programmed cycles entered by the user by holding down the
Clock
Button
in the initial screen for approx. five seconds. Do not release the button until the text CLEAR TIMERS CLEARED appears on
the screen. Only the appearance of the words CLEARED signal that the previously entered programmed cycles have been deleted.
5.5 LEVEL: OPERATING LEVEL SETTING
The appliance
must be energised and the I/0 switch in position “I".
Your appliance is delivered with an excellent program installed that favours combustion efficiency; the program is called
LEVEL 1
.
However, if you are using pellets with a higher than normal incidence of residues after combustion in the brazier, it is possible to
select alternative levels: