INSTALLATION, USE AND MAINTENANCE GUIDE
POPSTAR 6
– POPSTAR 10
Page
37
ENG
UNBURNT PELLETS IN
THE BRAZIER
EXCESSIVE DRAUGHT IN THE FLUE OUTLET
THE FOLLOWING ALARM IS SHOWN ON THE DISPLAY
“NO PELLET”
HAVE THE FLUE OUTLET DRAUGHT CHECKED AND IF
NECESSARY MAKE THE APPROPRIATE MODIFICATIONS
THE TIME DOES NOT
REMAIN IN THE MEMORY
THE BUFFER BATTERY INSTALLED IN THE CONTROL PANEL IS EXHAUSTED
REPLACE THE BATTERY
THE HOURLY PROGRAM
IS NOT COMPLIED WITH
THE USER HAS NOT ENABLED IT
PRESS THE CLOCK BUTTON TO ENABLE IT AS
INSTRUCTED IN THIS USE AND MAINTENANCE GUIDE
THE BUFFER BATTERY INSTALLED IN THE CONTROL PANEL IS EXHAUSTED
REPLACE THE BATTERY
AN ERROR HAS BEEN MADE WITHIN THE PROGRAMMED CYCLE: A SHUT OFF
TIME HAS BEEN SET BEFORE THE START TIME
VERIFY THE TIMES SET IN THE CRONO SCREEN
AFTER A FEW HOURS OF
OPERATION A DEPOSIT
APPEARS ON THE GLASS
THIS PROBLEM OCCURS IN NEW PRODUCTS AND IS CAUSED BY THE
EVAPORATION OF SOLVENTS PRESENT IN THE SILICONE
CLEAN THE GLASS WITH A NON-ABRASIVE WET CLOTH
IF THE REMEDIES SUPPLIED HERE DO NOT SOLVE THE PROBLEM YOU HAVE ENCOUNTERED OR IF YOU REQWUIRE SPARE PARTS
CONTACT AN AUTHORISED TECHNICAL SUPPORT CENTRE