Page 35
Installation, use and maintenance guide
THE BURNER IS NOT PROPERLY PLACED
ON ITS SEAT
OR IT STAYS LIFTED FROM ITS SEAT
EMPTY THE BURNER AND CLEAN
IT UP AS INDICATED IN PARA. 8.
THEN SET THE BURNER ON ITS
SEAT PROPERLY
OCCURS THE FIRST TIME THE APPLIANCE
IS SWITCHED ON AS THE SILICONE PAINT
IS BEING BAKED
RUN THE APPLIANCE UNDER
NORMAL OPERATING CONDITIONS
FOR A FEW DAYS
THE SMOKE EXHAUST IS NOT SEALED
CORRECTLY
CHECK IF THE FLUE OUTLET IS
SEALED CORRECTLY
CHECK THE CONDITION OF THE
OUTLET TUBES AND IF THE
GASKETS ARE SEALED
CORRECTLY
IF THE APPLIANCE STARTS TO SMOKE
AFTER 25 MINUTES:
DIRTY BURNER, VERY DELAYED START.
EMPTY THE BURNER AND CLEAN
IT UP AS INDICATED IN PARA. 8.
IF THE APPLIANCE STARTS TO SMOKE
AFTER 25 MINUTES:
DELAYED START BECAUSE THE SCREW
FEEDER IS EMPTY
EMPTY THE BURNER AND CLEAN
IT UP AS INDICATED IN PARA. 8.
THEN FILL UP THE HOPPER.
THE APPLIANCE
SMOKES
SMOKE PURGE VALVE TRIPPING
FOLLOW ALL THE CLEANING AND
MAINTENANCE INSTRUCTIONS
SET OUT IN PARA. 8, INCLUDING
THE CLEANING OF THE FLUE
OUTLET
DELAYED START BECAUSE THE SCREW
FEEDER IS EMPTY
(DISPLAY SHOWS THE INSCRIPTION AL
AC)
EMPTY THE BURNER AND CLEAN
IT UP AS INDICATED IN PARA. 8.
THEN FILL UP THE TANK
THE APPLIANCE SHUTS
OFF A FEW MINUTES
AFTER THE END OF THE
START UP CYCLE
DIRTY BURNER, VERY DELAYED START
(DISPLAY SHOWS THE INSCRIPTION AL
AC)
EMPTY THE BURNER AND CLEAN
IT UP AS INDICATED IN PARA. 8.
THEN FILL UP THE TANK
THE APPLIANCE DOES
NOT START UP
THE SPARK PLUG IS DAMAGED
(DISPLAY SHOWS THE INSCRIPTION AL
AC)
EMPTY THE BURNER AND CLEAN
IT UP AS INDICATED IN PARA. 8.
THEN REPLACE THE SPARK PLUG.
THE APPLIANCE ACCUMULATES PELLETS
IN THE BRAZIER
CLEAN THE GLASS MORE OFTEN.
FOLLOW THE CLEANING AND
MAINTENANCE INSTRUCTIONS OF
THE APPLIANCE (SEE PARA. 8)
SET THE OPERATING PROGRAM
“Level 2”
THE APPLIANCE OPERATES WITH
FREQUENT ON-OFF CYCLES
THE APPLIANCE NEEDS TO
OPERATE AT A HIGHER POWER
LEVEL TO REDUCE THE ON/OFF
ACTIONS.
THE GLASS IS COVERED
IN BLACK SOOT
THE CAST BLADE POSITION IS NOT
CORRECT/ NO BLADE
POSITION THE BLADE CORRECTLY
/ MOUNT THE BLADE
ROOM TEMPERATURE THERMOSTAT IS
SET TOO LOW
THE APPLIANCE OPERATES AT INTERVALS
THE APPLIANCE MUST OPERATE
FOR MORE HOURS WITH MORE
POWER: SET A HIGHER
TEMPERATURE
THE ROOM IS TOO LARGE, THE WALLS
ARE COLD.
SEPARATE THE SPACES
THE APPLIANCE SHOULD
OPERATE FOR MORE TIME AND
WITH MORE POWER
POOR PELLETS
USE A DIFFERENT TYPE OF
PELLETS IN COMPLIANCE WITH
OM 7135
THE APPLIANCE SEEMS
NOT TO HEAT
CEILINGS TOO HIGH OR PRESENCE OF
STAIRS THAT DISPERSE THE HEAT
ELSEWHERE.
SEPARATE THE SPACES
THE APPLIANCE SHOULD
OPERATE FOR MORE TIME AND
WITH MORE POWER
THE APPLIANCE IS OFF
PELLET HOPPER IS EMPTY (DISPLAY
EMPTY THE BURNER AND CLEAN