Page 36
Installation, use and maintenance guide
SlimQuadro Idra 14
ATTENTION: The STOP mode must be considered an overtemperature pre-allarm, and therefore cannot be considered a normal
operating stage.
WAIT ON: when the appliance is restarted while hot where the water temperature is higher than 63°C the appliance does not start
immediately, but the circulating pump will still be active. The message WAIT ON appears on the display. A new startup procedure
will not begin until the temperature drops to 58°C. The text START will appear on the screen.
SUN OUT: this function only activates automatically if the THERMOCONTROL function is turned to ON and if solar panels are
connected to the puffer. When Sensor S2 detects a temperature over 80°C and the appliance is in OFF mode, the text SUNOUT
will appear on the display accompanied by the circulating pump active indicator and activation of the smoke suction unit at the
maximum power.
When the temperature of sensor S2 drops below 75°C, the SUNOUT text deactivates and OFF appears in its place; the circulating
pump and the smoke suction unit switch off.
This guarantees the dissipation of the excess heat from the solar panels, a situation that could easily arise on the Summer days.
WAIT TIME: The Chrono programming has been activated and the appliance is waiting for the first scheduled ON cycle to activate
itself; it is similar to the OFF cycle except that in this function the appliance waits for the time programmed by the user to reactivate.
NO PROGRAM: The Chrono programming has been activated by pressing the clock button, but no valid programming was made.
6.10.2 SETTING RANGE
Heat transfer occurs according to the anticondensation principle, that is by activating the circulating pump at 61°C. Activating the
circulating pump at a lower temperature could lead to the formation of acid condensation which is extremely harmful for the
components of the appliance and seriously affect their duration.
6.10.3 AUTOMATIC CYCLE
In the automatic cycle the appliance expresses its maximum operating flexibility by optimising the fuel consumption. To activate the
AUTO cycle, select the power bars up to the sixth bar containing the text
AUTO.
During the AUTO cycle the appliance self-regulates the combustion function according to the temperature of the water in the boiler
set with the
Degrees Button. The setting range is between 65°C and 73°C.
ATTENTION: We recommend against activating the Auto function if the THERMOCONTROL function is active in the
appliance.
Example:
If for example the temperature is set at 70°C the five speed levels will be automatically distributed between 61°C and 70°C so that
with a temperature set at 70°C the appliance is at its minimum power level.
If the temperature value is increased or reduced all the power levels will be redistributed along the new temperature range. We
therefore recommend finding the correct temperature in order to optimise the full potential of the produced heat..
If the value is set at a high temperature, let's say 73°C, the appliance will attempt to reach that level as quickly as possible by
modulating the power as it approaches the set temperature. It is not necessary to set high t max temperatures when the ambient
conditions do not require them. Time and experience in using the appliance will give you the possibility of determining which are the
most appropriate SET POINTS for your needs. If the combustion power is not absorbed by the system above a temperature of 80°
C the appliance will temporarily shut down and the word STOP will appear in the display. Reactivation will occur automatically when
the temperature drops to 58°C.
Potenza di funzionamento
Intervallo modulazione con T max 65°c
65 °c
5
4
3
2
1
80 °c
STOP
61 °c
Intervallo modulazione con T max 70°c
Potenza di funzionamento
61 °c
5
4
3
70 °c
2
1
80 °c
STOP
Legenda
Key
Potenza di funzionamento
Operating power
Intervallo di modulazione
con T max
Modulation frequency with
T max