16
Low voltage
max. 12VAC/DC connection
Terminal: Connection
for:
S1 (2x)
Sensor 1 storage
S2 (2x)
Sensor 2 (optional)
S3 (2x)
Sensor 3 (optional)
The polarity of the sensors S1-S3 is freely selectable.
V1 / -
0-10V or PWM +/- ( SR14 Version 3+4)
Mains voltages 230 VAC 50-60Hz
Terminal: Connection
for:
L
Mains phase conductor L
N
Mains neutral conductor N
R
Pump phase conductor L
N
Pump neutral conductor N
R
Break contact ( SR14 Version 1+3)
The
PE protective conductor
must be connected to
the PE metal terminal block!
When S2 is installed = S1
is switch-on sensor and S2
switch-off sensor.
Installation
Low voltage
max. 12VAC/DC connection
Terminal: Connection
for:
S1 (2x)
Sensor 1 storage
S2 (2x)
Sensor 2 backward
fl
ow
S3 (2x)
Sensor 3 (optional)
The polarity of the sensors S1-S3 is freely selectable.
V1 / -
0-10V or PWM +/- ( SR14 Version 3+4)
Mains voltages 230 VAC 50-60Hz
Terminal: Connection
for:
L
Mains phase conductor L
N
Mains neutral conductor N
R
Valve phase conductor L
N
Valve neutral conductor N
R
Break contact ( SR14 Version 1+3)
The
PE protective conductor
must be connected to
the PE metal terminal block!
D.5
Raising of heat circuit
D.6 Thermostat
Sensor side
max. 12V
Caution
Mains side
230 AC
Danger
Sensor side
max. 12V
Caution
Mains side
230 AC
Danger
Caution
Actuating direction of valve:
R1 on/valve on = direction
through the storage tank